Full Text:   <6057>

CLC number: TU39

On-line Access: 2013-01-31

Received: 2011-11-16

Revision Accepted: 2012-02-22

Crosschecked: 2013-01-23

Cited: 5

Clicked: 17640

Citations:  Bibtex RefMan EndNote GB/T7714

-   Go to

Article info.
Open peer comments

Journal of Zhejiang University SCIENCE A 2013 Vol.14 No.2 P.120-136

http://doi.org/10.1631/jzus.A1100316


Ultimate strength of single shear bolted connections with cold-formed ferritic stainless steel*


Author(s):  Jin-seong Lim, Tae-soo Kim, Seung-hun Kim

Affiliation(s):  . Department of Architectural Engineering, Hanbat National University, Daejeon 305-719, Korea

Corresponding email(s):   tskim@hanbat.ac.kr

Key Words:  Cold-formed ferritic stainless steel, Bolted connection, Bolt arrangement, End distance, Curling, Strength reduction


Jin-seong Lim, Tae-soo Kim, Seung-hun Kim. Ultimate strength of single shear bolted connections with cold-formed ferritic stainless steel[J]. Journal of Zhejiang University Science A, 2013, 14(2): 120-136.

@article{title="Ultimate strength of single shear bolted connections with cold-formed ferritic stainless steel",
author="Jin-seong Lim, Tae-soo Kim, Seung-hun Kim",
journal="Journal of Zhejiang University Science A",
volume="14",
number="2",
pages="120-136",
year="2013",
publisher="Zhejiang University Press & Springer",
doi="10.1631/jzus.A1100316"
}

%0 Journal Article
%T Ultimate strength of single shear bolted connections with cold-formed ferritic stainless steel
%A Jin-seong Lim
%A Tae-soo Kim
%A Seung-hun Kim
%J Journal of Zhejiang University SCIENCE A
%V 14
%N 2
%P 120-136
%@ 1673-565X
%D 2013
%I Zhejiang University Press & Springer
%DOI 10.1631/jzus.A1100316

TY - JOUR
T1 - Ultimate strength of single shear bolted connections with cold-formed ferritic stainless steel
A1 - Jin-seong Lim
A1 - Tae-soo Kim
A1 - Seung-hun Kim
J0 - Journal of Zhejiang University Science A
VL - 14
IS - 2
SP - 120
EP - 136
%@ 1673-565X
Y1 - 2013
PB - Zhejiang University Press & Springer
ER -
DOI - 10.1631/jzus.A1100316


Abstract: 
This paper is focused on the structural behavior of the single shear bolted connections with thin-walled ferritic stainless steel. The purpose of this study is to investigate the ultimate behaviors, such as ultimate strength and fracture mode of the single shear bolted connections of thin-walled ferritic stainless steel (low cost steel) rather than austenitic stainless steel (high cost steel). bolt arrangement and end distance parallel to the direction of applied load are considered as main variables of the test specimens for bolted connections. Specimens have a constant dimension of edge distance perpendicular to the loading direction, bolt diameter, pitch, and gauge. A monotonic tensile test for specimens has been carried out and some bolted connections with long end distance showed curling (out of plane deformation) occurrence which led to strength reduction. The ultimate behaviors such as fracture mode, ultimate strength are compared with those predicted by current design codes. Further, conditions of curling occurrence and the strength reduction due to curling are investigated and modified strength equations are suggested considering the curling effect.

Darkslateblue:Affiliate; Royal Blue:Author; Turquoise:Article

References

[1] AISI (American Iron and Steel Institute), 1968.  Specification for the Design of Light Gage Cold-Formed Stainless Steel Structural Members. AISI,USA :

[2] AISI (American Iron and Steel Institute), 1974.  Stainless Steel Cold-Formed Structural Design Manual. AISI,USA :

[3] AISI S100-07, 2007.  North American Specification for the Design of Cold-Formed Steel Structural Members. American Iron and Steel Institute (AISI),Washington DC, USA :

[4] AISC (American Institute of Steel Construction), 2005.  Specification for Structural Steel Buildings. AISC,USA :

[5] AIJ (Architectural Institute of Japan), 2002.  Recommendation for Limit State Design of Steel Structures. AIJ,Tokyo, Japan :

[6] AIJ (Architectural Institute of Japan), 2002.  Recommendation for the Design and Fabrication of Light Weight Steel Structures. AIJ,Tokyo, Japan :

[7] AS/NZS 4673, 2001.  Cold-Formed Stainless Steel Structures. Australian Standard/New Zealand Standard (AS/NZS),Australia :

[8] ASTM A370-10, 2010.  Standard Test Methods and Definitions for Mechanical Testing of Steel Products. American Society for Testing and Materials (ASTM),USA :

[9] EN 1993-1-4, 2006. Eurocode 3: Design of Steel Structures–Part 1.4: General Rules–Supplementary Rules for Stainless Steel. , European Committee for Standardization (CEN),:

[10] JIS G 4321, 2010.  Stainless Steel for Building Structure. Japan Industrial Standards (JIS),Tokyo, Japan :

[11] JIS Z 2241, 2010.  Method of Tensile Test for Metallic Materials. Japan Industrial Standards (JIS),Tokyo, Japan :

[12] Johnson, A.L., Winter, G., 1966. Behavior of stainless steel columns and beams. Journal of Structure Division, 92(10):97-118. 

[13] Kim, T.S., Kuwamura, H., 2007. Finite element modeling of bolted connections in thin-walled stainless steel plates under static shear. Thin-Walled Structures, 45(4):407-421. 


[14] Kim, T.S., Kuwamura, H., Cho, T.J., 2008. A parametric study on ultimate strength of single shear bolted connections with curling. Thin-Walled Structures, 46(1):38-53. 


[15] Kim, T.S., Kuwamura, H., Kim, S.H., Lee, Y.T., Cho, T.J., 2009. Investigation on ultimate strength of thin-walled steel single shear bolted connections with two bolts using finite element analysis. Thin-Walled Structures, 47(11):1191-1202. 


[16] Kuwamura, H., 2001.  Experimental Report on Strength of Bolted Connections in Thin-Walled Plates. Steel Structure Laboratory,the University of Tokyo, Tokyo, Japan :

[17] Kuwamura, H., Isozaki, A., 2002. Ultimate behavior of fastener connections of thin stainless steel plates. Journal of Structural and Construction Engineering (Transactions of Architectural Institute of Japan), (in Japanese),556:159-166. 

[18] Nethercot, D.A., Salih, E.L., Gardner, L., 2011. Behaviour and design of stainless steel bolted connections. Advances in Structural Engineering, 14(4):51-62. 


[19] Salih, E.L., Gardner, L., Nethercot, D.A., 2010. Numerical investigation of net section failure in stainless steel bolted connections. Journal of Constructional Steel Research, 66(12):1455-1466. 


[20] Salih, E.L., Gardner, L., Nethercot, D.A., 2011. Bearing failure in stainless steel bolted connections. Engineering Structures, 33(2):549-562. 


[21] SEI/ASCE-8-02, 2002.  Specification for the Design of Cold-Formed Stainless Steel Structural Members. American Society of Civil Engineers (ASCE),USA :

[22] SSBA (Stainless Steel Building Association of Japan), 2006.  Design Manual of Light-Weight Stainless Steel Structures. SSBA,Tokyo, Japan :


Open peer comments: Debate/Discuss/Question/Opinion

<1>

Please provide your name, email address and a comment





Journal of Zhejiang University-SCIENCE, 38 Zheda Road, Hangzhou 310027, China
Tel: +86-571-87952783; E-mail: cjzhang@zju.edu.cn
Copyright © 2000 - 2024 Journal of Zhejiang University-SCIENCE