Publishing Service

Polishing & Checking

Journal of Zhejiang University SCIENCE A

ISSN 1673-565X(Print), 1862-1775(Online), Monthly

Removal of cyclops in pre-oxidizing cooperation water treatment process

Abstract: Zooplankton cyclops propagates profusely in waterbody, cannot be effectively inactivated by conventional disinfection process, and becomes a troublesome drinking water treatment problem. In this work, the qualitative and quantitative experimental studies were carried out on inactivation of zooplankton cyclops using oxidants, such as chlorine (Cl2), chlorine dioxide (ClO2), ozone (O3), hydrogen peroxide (H2O2), ozone/hydrogen peroxide (O3/H2O2), chloramines (Cl2-NH3) and potassium permanganate (KMnO4). The influences of various factors include different oxidant dosages, organic substance contents and pH values. The results showed that currently available oxidants used all might inactivate cyclops in some extent. According to the experimental results, chlorine dioxide, ozone, ozone/hydrogen peroxide and chloramines can be selected as effective oxidants for inactivating cyclops because of their strong inactivation abilities. Then the synergic removal effects on cyclops with ozone, ozone/hydrogen peroxide pre-oxidation followed by conventional water treatment processes were investigated. The results showed that ozone and ozone/hydrogen peroxide pre-oxidation can inactivate cyclops effectively, which then can be removed thoroughly by conventional water treatment processes. Cyclops cannot appear in water after filtration with 1.65 mg/L of ozone and 6 mg/L of hydrogen peroxide, with the inactivation rate being 62% before conventional water treatment processes. Cyclops cannot appear in water after filtration with 1.8 mg/L of ozone, with the inactivation rate being 50% before conventional water treatment processes. For different oxidants, when removal rate was the best, the inactivation rate was not the same. These results may provide reference and model for actual waterworks.

Key words: Cyclops of zooplankton, Water treatment, Inactivation, O3, O3/H2O2 pre-oxidation


Share this article to: More

Go to Contents

References:

<Show All>

Open peer comments: Debate/Discuss/Question/Opinion

<1>

Please provide your name, email address and a comment





DOI:

10.1631/jzus.2007.A1826

CLC number:

TU991

Download Full Text:

Click Here

Downloaded:

3236

Clicked:

5743

Cited:

3

On-line Access:

Received:

2007-01-22

Revision Accepted:

2007-05-20

Crosschecked:

Journal of Zhejiang University-SCIENCE, 38 Zheda Road, Hangzhou 310027, China
Tel: +86-571-87952276; Fax: +86-571-87952331; E-mail: jzus@zju.edu.cn