Development of non-premixed porous inserted regenerative thermal oxidizer

Abstract: In this study, a porous inserted regenerative thermal oxidizer (PRTO) system was developed for a 125 kW industrial copper-melting furnace, due to its advantages of low NOx emissions and high radiant efficiency. Zirconium dioxide (ZrO2) ceramic foams were placed into the combustion zone of a regenerative thermal oxidizer (RTO). Different performance characteristics of the RTO and PRTO systems, including pressure drop, temperature distribution, emissions, and energy efficiency, were evaluated to study the effects of the porous inserts on non-premixed CH4 combustion. It was found that the PRTO system achieved a significant reduction in the NOx emission level and a fuel saving of approximately 30% compared to the RTO system. It is most suitable for a lean combustion process at an equivalence ratio <0.4 with NOx and CO emission levels within 0.002%–0.003% and 0.001%–0.002%, respectively.

Key words: Porous media, Regenerative thermal oxidizer (RTO), Non-premixed CH4 combustion


Share this article to: More

Go to Contents

References:

<Show All>

Open peer comments: Debate/Discuss/Question/Opinion

<1>

Please provide your name, email address and a comment





DOI:

10.1631/jzus.A1300198

CLC number:

TK16

Download Full Text:

Click Here

Downloaded:

11837

Download summary:

<Click Here> 

Downloaded:

2821

Clicked:

8165

Cited:

0

On-line Access:

2024-08-27

Received:

2023-10-17

Revision Accepted:

2024-05-08

Crosschecked:

2013-08-20

Journal of Zhejiang University-SCIENCE, 38 Zheda Road, Hangzhou 310027, China
Tel: +86-571-87952276; Fax: +86-571-87952331; E-mail: jzus@zju.edu.cn
Copyright © 2000~ Journal of Zhejiang University-SCIENCE