WIND-INDUCED STOCHASTIC RESPONSE OF CONTROLLED TALL BUILDINGS BY COMPLEX-MODE ANALYSIS
Abstract: This paper deals with the along-wind dynamic response of tall buildings passively controlled by Cross-Tensioned Spring Damper (CTSD) mechanisms. In order to estimate the dynamic response more accurately and efficiently, the building and its CTSD controllers were considered as a coupled non-classical damping system and a new stochastic response analysis method, complex-modal state-space method, was proposed based on the combination of complex modes of the structural system rather than on the real-modal decomposition as usual. As numerical examples, the displacement response of a 2-degree-of freedom system to white-nosie input is first considered and the validity and accuracy of the proposed method are demonstrated through comparison with the exact results. The wind-induced dynamic responses of a tall building controlled by two CTSD mechanisms are the analyzed. The calculation results showed that the proposed method is much more appropriate and accurate than the conventional real-modal decomposition method in the analysis of dynamic responses of passively controlled tall buildings.
Key words: tall building, wind-induced vibration, structual control, complex-mode analysis, state-space mode
References:
Open peer comments: Debate/Discuss/Question/Opinion
<1>
DOI:
10.1631/jzus.2000.0421
CLC number:
TU311.3, TU973
Download Full Text:
Downloaded:
2682
Clicked:
6113
Cited:
1
On-line Access:
2024-08-27
Received:
2023-10-17
Revision Accepted:
2024-05-08
Crosschecked: