Journal of Zhejiang University SCIENCE A
ISSN 1673-565X(Print), 1862-1775(Online), Monthly
2005 Vol.6 No.7 P.722-727
Constant-step stress accelerated life test of VFD under Weibull distribution case
Abstract: Constant-step stress accelerated life test of Vacuum Fluorescent Display (VFD) was conducted with increased cathode temperature. Statistical analysis was done by applying Weibull distribution for describing the life, and Least Square Method (LSM) for estimating Weibull parameters. Self-designed special software was used to predict the VFD life. Numerical results showed that the average life of VFD is over 30000 h, that the VFD life follows Weibull distribution, and that the life-stress relationship satisfies linear Arrhenius equation completely. Accurate calculation of the key parameter enabled rapid estimation of VFD life.
Key words: Vacuum Fluorescent Display, Accelerated life test, Constant-step, Weibull, Average life
References:
Open peer comments: Debate/Discuss/Question/Opinion
<1>
DOI:
10.1631/jzus.2005.A0722
CLC number:
TN141
Download Full Text:
Downloaded:
3466
Clicked:
7084
Cited:
0
On-line Access:
2024-08-27
Received:
2023-10-17
Revision Accepted:
2024-05-08
Crosschecked: