Diagnosis of stator faults in induction motor based on zero sequence voltage after switch-off

Abstract: To improve the accuracy of the stator winding fault diagnosis in induction motor, a new diagnostic method based on the Hilbert-Huang transform (HHT) was proposed. The ratio of fundamental zero sequence voltage to positive sequence voltage after switch-off was selected as the stator fault characteristic, which could effectively avoid the influence of the supply unbalance and the load fluctuation, and directly represent the asymmetry in the stator. Using the empirical mode decomposition (EMD) based on HHT, the zero sequence voltage after switch-off was decomposed and the fundamental component was extracted. Then, the fault characteristic can be acquired. Experimental results on a 4-kW induction motor demonstrate the feasibility and effectiveness of this method.

Key words: Induction motor, Stator fault diagnosis, Hilbert-Huang transform (HHT), Zero sequence voltage, Empirical mode decomposition (EMD)


Share this article to: More

Go to Contents

References:

<Show All>

Open peer comments: Debate/Discuss/Question/Opinion

<1>

Please provide your name, email address and a comment





DOI:

10.1631/jzus.A071297

CLC number:

TM343

Download Full Text:

Click Here

Downloaded:

3613

Clicked:

5737

Cited:

0

On-line Access:

Received:

2007-06-08

Revision Accepted:

2007-08-31

Crosschecked:

Journal of Zhejiang University-SCIENCE, 38 Zheda Road, Hangzhou 310027, China
Tel: +86-571-87952276; Fax: +86-571-87952331; E-mail: jzus@zju.edu.cn
Copyright © 2000~ Journal of Zhejiang University-SCIENCE