Removal of copper ions from electroplating rinse water using electrodeionization

Abstract: An improved configuration of the membrane stack was adopted in the electrodeionization (EDI) cell to prevent precipitation of bivalent metal hydroxide during the running. The operational parameters that influenced the removal of copper ions from the dilute solution were optimized. The result showed that a moderate decrease in the inlet pH value and a moderate increase in the applied voltage could achieve a better removal effect. The steady process of electroplating wastewater treatment could be achieved with a removal efficiency of more than 99.5% and an enrichment factor of 5~14. The concentration of copper in purified water was less than 0.23 mg/L. This demonstrated the applicability of recovering heavy metal ions and purified water from electroplating effluent for industrial reuse.

Key words: Electrodeionization (EDI), Electroplating wastewater, Heavy metal, Precipitation


Share this article to: More

Go to Contents

References:

<Show All>

Open peer comments: Debate/Discuss/Question/Opinion

<1>

Please provide your name, email address and a comment





DOI:

10.1631/jzus.A0820166

CLC number:

X703.1

Download Full Text:

Click Here

Downloaded:

3473

Clicked:

5887

Cited:

16

On-line Access:

Received:

2008-03-06

Revision Accepted:

2008-06-02

Crosschecked:

Journal of Zhejiang University-SCIENCE, 38 Zheda Road, Hangzhou 310027, China