Journal of Zhejiang University SCIENCE A
ISSN 1673-565X(Print), 1862-1775(Online), Monthly
2009 Vol.10 No.11 P.1595-1600
Development of a linear compressor for two-stage pulse tube cryocoolers
Abstract: A valveless linear compressor was built up to drive a self-made two-stage pulse tube cryocooler. With a designed maximum swept volume of 60 cm3, the compressor can provide the cryocooler with a pressure volume (PV) power of 400 W. Preliminary measurements of the compressor indicated that both an efficiency of 35%~55% and a pressure ratio of 1.3~1.4 could be obtained. The two-stage pulse tube cryocooler driven by this compressor achieved the lowest temperature of 14.2 K.
Key words: Linear compressor, Linear motor, Pulse tube cryocooler