Publishing Service

Polishing & Checking

Journal of Zhejiang University SCIENCE A

ISSN 1673-565X(Print), 1862-1775(Online), Monthly

Behavior of axially loaded tubular X-joints using bolted connection: mechanical model and validation

Abstract: X-joints are one of the fundamental joint configurations used in a wide range of transmission tubular structures. Experimental investigation of four tubular X-joints with bolted connection was conducted in this study, and it was found that the annular plate was the main yielding control member of such X-joints. Moreover, the portion outside the effective width of the chord member still had a restriction effect on the annular plate, which led to reducing the yielding strength of the joint, while the gusset plate could help to improve the yield strength capacity. In the current design code of steel structures, the contribution to the strength capacity of the gusset plate has not been taken into account. Therefore, based on some mechanical assumptions, a general mechanical model was proposed. After the introduction of the gusset plate strength capacity factor, the yield capacity simplified calculation method of such X-joints was derived. Through the analyses of such X-joints with various diameters and thicknesses, it was concluded that a simple mechanical model could predict test results very well and that the contribution of the gusset plate was also taken into account.

Key words: Steel tubular X-joint, Bolted connection, Annular plate, Gusset plate, Strength capacity


Share this article to: More

Go to Contents

References:

<Show All>

Open peer comments: Debate/Discuss/Question/Opinion

<1>

mahdi@fathi<mah_13772000@yahoo.com>

2014-04-05 13:03:46

gusset plate

Please provide your name, email address and a comment





DOI:

10.1631/jzus.A1300207

CLC number:

TU375

Download Full Text:

Click Here

Downloaded:

2693

Clicked:

5577

Cited:

0

On-line Access:

2013-12-03

Received:

2013-06-16

Revision Accepted:

2013-11-04

Crosschecked:

2013-11-18

Journal of Zhejiang University-SCIENCE, 38 Zheda Road, Hangzhou 310027, China
Tel: +86-571-87952276; Fax: +86-571-87952331; E-mail: jzus@zju.edu.cn