Journal of Zhejiang University SCIENCE B
ISSN 1673-1581(Print), 1862-1783(Online), Monthly
2012 Vol.13 No.11 P.942-947
Establishment of reference mandibular plane for anterior alveolar morphology evaluation using cone beam computed tomography
Abstract: To propose a method of establishing the reference mandibular plane (MP), which could be reestablished according to the coordinates of the reference points, and then facilitate the assessment of anterior alveolar morphology using cone beam computed tomography (CBCT), sixty patients with bimaxillary protrusion were randomly selected and CBCT scans were taken. The CBCT scans were transferred to Materialism’s interactive medical image control system 10.01 (MIMICS 10.01), and three dimensional models of the entire jaws were constructed. Reference points determining the reference MP were positioned in the coronal, axial, sagittal windows, and the points were exactly located by recording their coordinates in the interfaces of software. The reference MP provided high intra-observer reliability (Pearson’s r 0.992 to 0.999), and inter-observer reliability (intra-class correlation coefficients (ICCs) 0.996 to 0.999).
Key words: Reference Plane, Cone beam computed tomography, Alveolar morphology
References:
Open peer comments: Debate/Discuss/Question/Opinion
<1>
DOI:
10.1631/jzus.B1200052
CLC number:
R783.5
Download Full Text:
Downloaded:
3662
Clicked:
6170
Cited:
4
On-line Access:
2024-08-27
Received:
2023-10-17
Revision Accepted:
2024-05-08
Crosschecked:
2012-10-19