Journal of Zhejiang University SCIENCE C
ISSN 1869-1951(Print), 1869-196x(Online), Monthly
2011 Vol.12 No.9 P.774-786
Interconnection and damping assignment and Euler-Lagrange passivity-based control of photovoltaic/battery hybrid power source for stand-alone applications
Abstract: A DC hybrid power source composed of photovoltaic cells as the main power source, Li-ion battery storage as the secondary power source, and power electronic interface, is modeled based on port-controlled Hamiltonian systems and Euler-Lagrange framework. Subsequently, passivity-based controllers are synthesized. Local asymptotic stability is ensured as well. In addition, a power management system is designed to manage power flow between components. Modeling and simulation of the proposed hybrid power source is accomplished using MATLAB/Simulink. Our interest is focused on the comparison of the two passivity-based control methods and their use in hybrid power systems.
Key words: DC hybrid power source, Euler-Lagrange (EL) equations, Interconnection and damping assignment (IDA), Passivity-based control, Photovoltaic, Li-ion battery
References:
Open peer comments: Debate/Discuss/Question/Opinion
<1>
DOI:
10.1631/jzus.C1000368
CLC number:
TP274; TM911.4
Download Full Text:
Downloaded:
4404
Clicked:
10051
Cited:
1
On-line Access:
2024-08-27
Received:
2023-10-17
Revision Accepted:
2024-05-08
Crosschecked:
2011-07-29