Journal of Zhejiang University SCIENCE A
ISSN 1673-565X(Print), 1862-1775(Online), Monthly
2007 Vol.8 No.3 P.335-510
Special Issue for selected papers of the 2nd International Conference on Reliability of Electrical Products and Electrical Contacts (ICREPEC 2007), Mar. 28~31, 2007, Xiamen, China
Electrical Product Reliability and Electrical Contact
Slade Paul G., Li Wang-Pei, Mayo Stephen, Smith R. Kirkland, Taylor Erik D.
DOI: 10.1631/jzus.2007.A0335 Downloaded: 4863 Clicked: 6968 Cited: 4 Commented: 0(p.335-342) <Full Text>
Reliability of power connections
BRAUNOVIC Milenko
DOI: 10.1631/jzus.2007.A0343 Downloaded: 4344 Clicked: 5882 Cited: 9 Commented: 0(p.343-356) <Full Text>
TAKAGI Tasuku
DOI: 10.1631/jzus.2007.A0357 Downloaded: 3364 Clicked: 5882 Cited: 0 Commented: 0(p.357-360) <Full Text>
Particle contamination, the disruption of electronic connectors in the signal transmission system
ZHANG Ji-gao
DOI: 10.1631/jzus.2007.A0361 Downloaded: 3737 Clicked: 6234 Cited: 0 Commented: 0(p.361-369) <Full Text>
Study on the instantaneous protection reliability of low voltage circuit breakers
LU Jian-guo, DU Tai-hang, LUO Yan-yan
DOI: 10.1631/jzus.2007.A0370 Downloaded: 3477 Clicked: 6867 Cited: 1 Commented: 0(p.370-377) <Full Text>
Transformer real-time reliability model based on operating conditions
HE Jian, CHENG Lin, SUN Yuan-zhang
DOI: 10.1631/jzus.2007.A0378 Downloaded: 4832 Clicked: 7266 Cited: 7 Commented: 0(p.378-383) <Full Text>
Failure analysis of a kind of low power connector
ZHOU Yi-lin, ZENG Ning, XU Liang-jun, JÖRGENS Stefan
DOI: 10.1631/jzus.2007.A0384 Downloaded: 3445 Clicked: 6466 Cited: 2 Commented: 0(p.384-392) <Full Text>
Approach for electrodynamic force for compensation in low voltage circuit breaker WP 630-1.2 type
LU Na, XU L.J., Miedziński B.
DOI: 10.1631/jzus.2007.A0393 Downloaded: 3724 Clicked: 6948 Cited: 0 Commented: 0(p.393-396) <Full Text>
Finite element model analysis of thermal failure in connector
WANG Xin, XU Liang-jun
DOI: 10.1631/jzus.2007.A0397 Downloaded: 3955 Clicked: 6452 Cited: 1 Commented: 0(p.397-402) <Full Text>
Modeling of contact surface morphology and dust particles by using finite element method
WANG Dong, XU Liang-jun
DOI: 10.1631/jzus.2007.A0403 Downloaded: 3544 Clicked: 6894 Cited: 7 Commented: 0(p.403-407) <Full Text>
Single neuron network PI control of high reliability linear induction motor for Maglev
FANG You-tong, FAN Cheng-zhi
DOI: 10.1631/jzus.2007.A0408 Downloaded: 3436 Clicked: 6340 Cited: 1 Commented: 0(p.408-411) <Full Text>
Dynamic performance analysis model of high-reliability EMS-Maglev system
FANG You-tong, YAO Ying-ying
DOI: 10.1631/jzus.2007.A0412 Downloaded: 3490 Clicked: 7660 Cited: 0 Commented: 0(p.412-415) <Full Text>
CUI Yu-long, LIU Hong, WANG Jing-qin, SUN Shu-guang
DOI: 10.1631/jzus.2007.A0416 Downloaded: 4605 Clicked: 6881 Cited: 1 Commented: 0(p.416-421) <Full Text>
Random vibration analysis of switching apparatus based on Monte Carlo method
ZHAI Guo-fu, CHEN Ying-hua, REN Wan-bin
DOI: 10.1631/jzus.2007.A0422 Downloaded: 3560 Clicked: 6603 Cited: 0 Commented: 0(p.422-425) <Full Text>
WANG Shu-juan, SHA You-tao, ZHANG Hui, ZHAI Guo-fu
DOI: 10.1631/jzus.2007.A0426 Downloaded: 3389 Clicked: 6679 Cited: 3 Commented: 0(p.426-433) <Full Text>
REN Wan-bin, CUI Li, LUO Fu-biao, ZHAI Guo-fu
DOI: 10.1631/jzus.2007.A0434 Downloaded: 3413 Clicked: 7053 Cited: 2 Commented: 0(p.434-438) <Full Text>
Discussion on dynamic reliability tolerance design technology of electromagnetic relay
YE Xue-rong, LIANG Hui-min, ZHAI Guo-fu
DOI: 10.1631/jzus.2007.A0439 Downloaded: 3506 Clicked: 6431 Cited: 0 Commented: 0(p.439-443) <Full Text>
Dynamics analysis of vibration process in Particle Impact Noise Detection
ZHANG Hui, ZHOU Chang-lei, WANG Shu-juan, ZHAI Guo-fu
DOI: 10.1631/jzus.2007.A0444 Downloaded: 3706 Clicked: 7512 Cited: 1 Commented: 0(p.444-448) <Full Text>
Study on the failure mechanism of Ag-Ce contacts in DC level
MENG Fan-bin, LU Jian-guo, LU Ning-yi, CHEN Zhi-chao, CHEN Qi
DOI: 10.1631/jzus.2007.A0449 Downloaded: 3433 Clicked: 6061 Cited: 0 Commented: 0(p.449-452) <Full Text>
Research on the overload protection reliability of moulded case circuit-breakers and its test device
LI Kui, LU Jian-guo, WU Yi, QIN Zhi-jun, YAO Dong-mei
DOI: 10.1631/jzus.2007.A0453 Downloaded: 3107 Clicked: 6495 Cited: 1 Commented: 0(p.453-458) <Full Text>
Testing results analysis of contact materials’ electrical contact performance
WANG Jing-qin, WANG Hai-tao, WEN Ming, ZHU Yan-cai
DOI: 10.1631/jzus.2007.A0459 Downloaded: 3757 Clicked: 6186 Cited: 2 Commented: 0(p.459-463) <Full Text>
Research of network technology for Intelligent Circuit Breaker Controller
LIU Jiao-min, FAN Tong-rang, TONG Kuan-zhang
DOI: 10.1631/jzus.2007.A0464 Downloaded: 3403 Clicked: 6666 Cited: 4 Commented: 0(p.464-468) <Full Text>
New method for capturing arc of moving on switching apparatus
LIU Jiao-min, WANG Jing-hong
DOI: 10.1631/jzus.2007.A0469 Downloaded: 3185 Clicked: 6074 Cited: 0 Commented: 0(p.469-474) <Full Text>
Reliability testing and reliability analysis of the over-load protective relay
ZHAO Jing-ying, CHEN Hong-jian, LIU Guo-jin, ZHANG Yong, WU Pin-hua
DOI: 10.1631/jzus.2007.A0475 Downloaded: 3483 Clicked: 6566 Cited: 1 Commented: 0(p.475-480) <Full Text>
Study on reliability technology of contactor relay
LIU Guo-jin, ZHAO Jing-ying, WANG Hai-tao, YANG Chen-guang, SUN Shun-li
DOI: 10.1631/jzus.2007.A0481 Downloaded: 4718 Clicked: 6376 Cited: 1 Commented: 0(p.481-484) <Full Text>
YAO Fang, ZHENG Jian-rong, HUANG Zhang-wu
DOI: 10.1631/jzus.2007.A0485 Downloaded: 3236 Clicked: 6247 Cited: 1 Commented: 0(p.485-489) <Full Text>
Design of intelligent detecting system based on wireless transmission
GUO Li-wei, LIU Dong-hui, ZHANG Xin-ling, SUN Xiao-yun
DOI: 10.1631/jzus.2007.A0490 Downloaded: 3224 Clicked: 6257 Cited: 1 Commented: 0(p.490-494) <Full Text>
Inspection-replacement policy of system under predictive maintenance
LIU Bao-you, FANG You-tong, WEI Jin-xiang, WANG Yong-liang
DOI: 10.1631/jzus.2007.A0495 Downloaded: 3289 Clicked: 5975 Cited: 1 Commented: 0(p.495-500) <Full Text>
Application of the Bayes’ theory to the failure rate evaluation of electrical apparatus
JIN Shao-hua, LU Jian-guo, WAN Yan-ping, SUN Shu-guang
DOI: 10.1631/jzus.2007.A0501 Downloaded: 3349 Clicked: 6383 Cited: 2 Commented: 0(p.501-505) <Full Text>
Technical research on optimization design of contacts of electrical connector
LV Bin, ZHOU Sheng-jun, ZHAO Lan-yan
DOI: 10.1631/jzus.2007.A0506 Downloaded: 3237 Clicked: 5932 Cited: 1 Commented: 0(p.506-510) <Full Text>