Development of an onsite calibration device for robot manipulators


Author(s):  Ziwei WAN, Chunlin ZHOU, Haotian ZHANG, Jun WU

Affiliation(s):  College of Control Science and Engineering, Zhejiang University, Hangzhou 310063, China; more

Corresponding email(s):   wanzw@zju.edu.cn, c_zhou@zju.edu.cn, zhanghtpex@163.com, junwuapc@zju.edu.cn

Key Words:  Calibration device, Kinematic calibration, Onsite calibration, Absolute accuracy


Ziwei WAN, Chunlin ZHOU, Haotian ZHANG, Jun WU. Development of an onsite calibration device for robot manipulators[J]. Frontiers of Information Technology & Electronic Engineering, 1998, -1(-1): .

@article{title="Development of an onsite calibration device for robot manipulators",
author="Ziwei WAN, Chunlin ZHOU, Haotian ZHANG, Jun WU",
journal="Frontiers of Information Technology & Electronic Engineering",
volume="-1",
number="-1",
pages="",
year="1998",
publisher="Zhejiang University Press & Springer",
doi="10.1631/FITEE.2200172"
}

%0 Journal Article
%T Development of an onsite calibration device for robot manipulators
%A Ziwei WAN
%A Chunlin ZHOU
%A Haotian ZHANG
%A Jun WU
%J Journal of Zhejiang University SCIENCE C
%V -1
%N -1
%P
%@ 2095-9184
%D 1998
%I Zhejiang University Press & Springer
%DOI 10.1631/FITEE.2200172

TY - JOUR
T1 - Development of an onsite calibration device for robot manipulators
A1 - Ziwei WAN
A1 - Chunlin ZHOU
A1 - Haotian ZHANG
A1 - Jun WU
J0 - Journal of Zhejiang University Science C
VL - -1
IS - -1
SP -
EP -
%@ 2095-9184
Y1 - 1998
PB - Zhejiang University Press & Springer
ER -
DOI - 10.1631/FITEE.2200172


Abstract: 
In this paper, a novel in-contact 3D measuring device, called MultiCal, is proposed as a convenient, low-cost (less than $5,000), and robust facility for onsite kinematic calibration and online measurement of robot manipulator accuracy. The device has µm-level accuracy and can be easily embedded in robot cells. During the calibration procedure, the robot manipulator first moves automatically to multiple end-effector orientations with its Tool Center Point (TCP) constrained on a fixed point by a 3D displacement measuring device (single point constraint), and the corresponding joint angles are recorded. Then, the measuring device is precisely mounted at different positions using a well-designed fixture, and the above measurement process is repeated to implement a multi-point constraint. The relative mounting positions are accurately measured and used as prior information to improve calibration accuracy and robustness. The results of the theoretical analysis indicate that MultiCal reduces calibration accuracy by 10% to 20% in contrast to traditional non-contact 3D or 6D measuring devices (such as laser trackers) when subject to the same level of artificial measurement noise. The result of a calibration experiment conducted on a Staubli TX90 robot shows that MultiCal has only 7% to 14% lower calibration accuracy compared to a measuring arm with a laser scanner, and 21% to 30% lower time efficiency compared to a 6D binocular vision measuring system, yielding maximum and mean absolute position errors of 0.831mm and 0.339mm, respectively.

Darkslateblue:Affiliate; Royal Blue:Author; Turquoise:Article

Open peer comments: Debate/Discuss/Question/Opinion

<1>

Please provide your name, email address and a comment





Journal of Zhejiang University-SCIENCE, 38 Zheda Road, Hangzhou 310027, China
Tel: +86-571-87952783; E-mail: cjzhang@zju.edu.cn
Copyright © 2000 - 2022 Journal of Zhejiang University-SCIENCE