CLC number: TU317
On-line Access: 2024-08-27
Received: 2023-10-17
Revision Accepted: 2024-05-08
Crosschecked: 2017-05-08
Cited: 0
Clicked: 5939
Citations: Bibtex RefMan EndNote GB/T7714
Zheng-gang Cao, Peng Du, Feng Fan, Zhe-ming Chen. Pseudo-dynamic testing of a fabricated composite frame with steel plate shear walls[J]. Journal of Zhejiang University Science A,in press.Frontiers of Information Technology & Electronic Engineering,in press.https://doi.org/10.1631/jzus.A1600022 @article{title="Pseudo-dynamic testing of a fabricated composite frame with steel plate shear walls", %0 Journal Article TY - JOUR
Abstract: In this manuscript, the authors investigated the seismic responses and failure modes of the fabricated steel frame with beam-only-connected steel plate shear walls and composite beams via pseudo-dynamic tests, and provided some design recommendations for this structural system. This experimental investigation is an innovative work, and such an attempt is of great interest.
装配式钢板剪力墙-组合框架结构伪动力试验研究创新点:1. 通过伪动力试验,研究了装配式组合框架结构的抗震性能;2. 分析了两边连接钢板剪力墙应用于装配式结构体系时的受力性能;3. 评估了设计规范ASCE/SEI 7-10中地震楼层剪力分布的合理性。 方法:1. 通过开展不同地震烈度下的伪动力试验研究,分析装配式钢板剪力墙-组合框架的地震响应和失效模式;2. 通过对比规范公式与试验数据,验证规范地震楼层剪力分布的合理性。 结论:1. 两边连接钢板剪力墙在较小的荷载下屈曲,通过屈曲后形成的拉力带抵抗水平荷载并屈服耗能;2. 由可变梁高装配式钢框架节点拼装而成的装配式组合框架具有稳定的力学性能、 良好的耗能能力以及足够的延性;3. 本文所分析的装配式框架试件在大震下发生了组合梁严重开裂以及钢板剪力墙与组合梁之间螺栓连接冲切破坏的现象,应通过合理设计避免该破坏模式;4. 设计规范ASCE/SEI 7-10所建议的公式可以合理地预测地震楼层剪力分布。 关键词组: Darkslateblue:Affiliate; Royal Blue:Author; Turquoise:Article
Reference[1]AISC (American Institute of Steel Construction), 2010. Seismic Provisions for Structural Steel Buildings, ANSI/AISC 341-10. AISC, USA. ![]() [2]ASCE (American Society of Civil Engineers), 2010. Minimum Design Loads for Buildings and Other Structures, ASCE/SEI 7-10. ASCE, USA. ![]() [3]Cao, Z.Z., Du, P., Li, J.D., et al., 2015. Research on mechanical performance of bolted height adjustable steel beam-to-column connections under low cycle reversed loading. Journal of Building Structures, 36(4):1-8 (in Chinese). ![]() [4]Clayton, P., Winkley, T., Berman, J., et al., 2012a. Experimental investigation of self-centering steel plate shear walls. Journal of Structural Engineering, 138(7):952-960. ![]() [5]Clayton, P., Berman, J., Lowes, L., 2012b. Seismic design and performance of self-centering steel plate shear walls. Journal of Structural Engineering, 138(1):22-30. ![]() [6]Dowden, D., Purba, R., Bruneau, M., 2012. Behavior of self-centering steel plate shear walls and design considerations. Journal of Structural Engineering, 138(1):11-21. ![]() [7]Driver, R., Kulak, G., Kennedy, D., et al., 1998. Cyclic test of four-storey steel plate shear wall. Journal of Structural Engineering, 124(2):112-120. ![]() [8]Guo, L.H., Rong, Q., Ma, X.B., et al., 2011. Behavior of steel plate shear wall connected to frame beams only. International Journal of Steel Structures, 11(4):467-479. ![]() [9]Kulkarni, S.A., Li, B., Yip, W.K., 2008. Finite element analysis of precast hybrid-steel concrete connections under cyclic loading. Journal of Constructional Steel Research, 64(2):190-201. ![]() [10]Li, B., Kulkarni, S.A., Leong, C.L., 2009. Seismic performance of precast hybrid-steel concrete connections. Journal of Earthquake Engineering, 13(5):667-689. ![]() [11]Lin, C.H., Tsai, K.C., Qu, B., et al., 2010. Sub-structural pseudo-dynamic performance of two full-scale two-storey steel plate shear walls. Journal of Constructional Steel Research, 66(12):1467-1482. ![]() [12]Liu, C., Wang, Q., Wang, Y., et al., 2013. Flexural behavior of precast reinforced concrete beams with steel end connectors. Journal of Building Structures, 34(S1):208-214 (in Chinese). ![]() [13]Lubell, A., Prion, H., Ventura, C., et al., 2000. Unstiffened steel plate shear wall performance under cyclic loading. Journal of Structural Engineering, 126(4):453-460. ![]() [14]MOHURD (Ministry of Housing and Urban-Rural Development of the People’s Republic of China), 1999. Steel and Steel Products―Location and Preparation of Test Pieces for Mechanical Testing, GB/T 2975-1998. MOHURD (in Chinese). ![]() [15]MOHURD (Ministry of Housing and Urban-Rural Development of the People’s Republic of China), 2010. Code for Seismic Design of Buildings, GB50011-2010. MOHURD (in Chinese). ![]() [16]MOHURD (Ministry of Housing and Urban-Rural Development of the People’s Republic of China), 2011. Metallic Materials-Tensile Testing―Part 1: Method of Test at Room Temperature, GB/T 228.1-2010. MOHURD (in Chinese). ![]() [17]MOHURD (Ministry of Housing and Urban-Rural Development of the People’s Republic of China), 2015. Specification for Seismic Test of Buildings, JGJ/T 101-2015. MOHURD (in Chinese). ![]() [18]MOHURD (Ministry of Housing and Urban-Rural Development of the People’s Republic of China), 2016. Technical Specification for Steel Plate Shear Walls, JGJ/T 380-2015. MOHURD (in Chinese). ![]() [19]Qu, B., Bruneau, M., Lin, C., et al., 2008. Testing of full-scale two-storey steel plate shear wall with reduced beam section connections and composite floors. Journal of Structural Engineering, 134(3):364-373. ![]() [20]Thorburn, L.J., Kulak, G.L., Montgomery, C.J., 1983. Analysis of Steel Plate Shear Walls. Structural Engineering Report No. 107. Department of Civil Engineering, the University of Alberta, Canada. Available from www.civil.ualberta.ca/structures/reports/SER107Thorburn,Kulak,andMontgomery.pdf. ![]() [21]Xue, M., Lu, L.W., 1994. Monotonic and cyclic behavior of infilled steel shear panels. 17th Czech and Slovak International Conference on Steel Structures and Bridges, p.152-160. ![]() [22]Yang, K.H., Oh, M.H., Kim, M.H., et al., 2010. Flexural behavior of hybrid precast concrete beams with H-steel beams at both ends. Engineering Structures, 32(9):2940-2949. ![]() Journal of Zhejiang University-SCIENCE, 38 Zheda Road, Hangzhou
310027, China
Tel: +86-571-87952783; E-mail: cjzhang@zju.edu.cn Copyright © 2000 - 2025 Journal of Zhejiang University-SCIENCE |
Open peer comments: Debate/Discuss/Question/Opinion
<1>