CLC number: TM464
On-line Access: 2024-08-27
Received: 2023-10-17
Revision Accepted: 2024-05-08
Crosschecked: 0000-00-00
Cited: 2
Clicked: 5832
BAO Jian-yu, BAI Zhi-hong, WANG Qing-song, ZHANG Zhong-chao. A new three-phase 5-level current-source inverter[J]. Journal of Zhejiang University Science A, 2006, 7(12): 1973-1978.
@article{title="A new three-phase 5-level current-source inverter",
author="BAO Jian-yu, BAI Zhi-hong, WANG Qing-song, ZHANG Zhong-chao",
journal="Journal of Zhejiang University Science A",
volume="7",
number="12",
pages="1973-1978",
year="2006",
publisher="Zhejiang University Press & Springer",
doi="10.1631/jzus.2006.A1973"
}
%0 Journal Article
%T A new three-phase 5-level current-source inverter
%A BAO Jian-yu
%A BAI Zhi-hong
%A WANG Qing-song
%A ZHANG Zhong-chao
%J Journal of Zhejiang University SCIENCE A
%V 7
%N 12
%P 1973-1978
%@ 1673-565X
%D 2006
%I Zhejiang University Press & Springer
%DOI 10.1631/jzus.2006.A1973
TY - JOUR
T1 - A new three-phase 5-level current-source inverter
A1 - BAO Jian-yu
A1 - BAI Zhi-hong
A1 - WANG Qing-song
A1 - ZHANG Zhong-chao
J0 - Journal of Zhejiang University Science A
VL - 7
IS - 12
SP - 1973
EP - 1978
%@ 1673-565X
Y1 - 2006
PB - Zhejiang University Press & Springer
ER -
DOI - 10.1631/jzus.2006.A1973
Abstract: The new three-phase 5-level current-source inverter (CSI) proposed in this paper was developed by connecting three separate single-phase 5-level CSIs in series, and its operational principle was analyzed. There are two major problems existing in current-source multilevel inverters, one is the complex PWM control method (2-logic to 3-logic conversion), and the other is the problem of current-unbalance between different levels. A simple current-balance control method via DC current feedback is applied in each single-phase 5-level CSI cell to implement the current-balance control between different levels. And to reduce the output current harmonics, POD PWM control technique was used. Simulation and experimental results showed that this new three-phase 5-level CSI topology operates correctly.
[1] Antunes, F.L.M., Braga, H.A.C., Barbi, I., 1999. Application of a generalized current multilevel cell to current-source inverters. IEEE Trans. on Industrial Electronics, 46(1):31-38.
[2] Bao, J.Y., Holmes, D.G., Bai, Z.H., Zhang, Z.C., Xu, D.H., 2006. PWM Control of a 5-level Single-phase Current-source Inverter with Controlled Intermediate DC-link Current. IEEE PESC2006, p.1633-1638.
[3] Karasik, V., Dixon, K., 1999. SMES for power utility applications: a review of technical and cost considerations. IEEE Trans. on Applied Superconductivity, 9(2):541-546.
[4] McGrath, B.P., Holmes, D.G., 2002. Multicarrier PWM strategies for multilevel inverters. IEEE Trans. on Industrial Electronics, 49(4):858-867.
[5] Peng, F.Z., 2001. A generalized multilevel inverter topology with self-voltage balancing. IEEE Trans. on Industrial Electronics, 37(2):611-618.
[6] Xiong, Y., Chen, D.J., Deng, S.Q., Zhang, Z.C., 2004. A New Single-phase Multilevel Current-source Inverter. IEEE APEC2004, p.1682-1685.
[7] Xiong, Y., Li, Y.L., Yang, X., Wei, K., Zhang, Z.C., 2005. A New Three-phase Five-level Current-source Inverter. IEEE APEC2005, p.424-427.
Open peer comments: Debate/Discuss/Question/Opinion
<1>