http://doi.org/10.1631/jzus.A1000095


A pilot field-scale study on biotrickling filter treatment of NH3-containing odorous gases from organic waste composting plants


Author(s):  Nian-tao Xue, Qun-hui Wang, Chuan-fu Wu, Xiao-hong Sun, Wei-min Xie

Affiliation(s):  Department of Environmental Engineering, School of Civil and Environmental Engineering, University of Science and Technology Beijing, Beijing 100083, China, Beijing Agricultural Biotechnology Centre, Beijing Academy of Agriculture and Forestry Sciences, Beijing 100089, China, Japan TOHIN Company Group Profile, Tokyo 346-0028, Japan

Corresponding email(s):   wangqh59@sina.com

Key Words:  Ammonia, Biotrickling filter, Odor, Organic waste composting, Pilot field-scale study, Trickling liquid


Share this article to: More |Next Article >>>

Nian-tao Xue, Qun-hui Wang, Chuan-fu Wu, Xiao-hong Sun, Wei-min Xie. A pilot field-scale study on biotrickling filter treatment of NH3-containing odorous gases from organic waste composting plants[J]. Journal of Zhejiang University Science A, 2010, 11(9): 629-637.

@article{title="A pilot field-scale study on biotrickling filter treatment of NH3-containing odorous gases from organic waste composting plants",
author="Nian-tao Xue, Qun-hui Wang, Chuan-fu Wu, Xiao-hong Sun, Wei-min Xie",
journal="Journal of Zhejiang University Science A",
volume="11",
number="9",
pages="629-637",
year="2010",
publisher="Zhejiang University Press & Springer",
doi="10.1631/jzus.A1000095"
}

%0 Journal Article
%T A pilot field-scale study on biotrickling filter treatment of NH3-containing odorous gases from organic waste composting plants
%A Nian-tao Xue
%A Qun-hui Wang
%A Chuan-fu Wu
%A Xiao-hong Sun
%A Wei-min Xie
%J Journal of Zhejiang University SCIENCE A
%V 11
%N 9
%P 629-637
%@ 1673-565X
%D 2010
%I Zhejiang University Press & Springer
%DOI 10.1631/jzus.A1000095

TY - JOUR
T1 - A pilot field-scale study on biotrickling filter treatment of NH3-containing odorous gases from organic waste composting plants
A1 - Nian-tao Xue
A1 - Qun-hui Wang
A1 - Chuan-fu Wu
A1 - Xiao-hong Sun
A1 - Wei-min Xie
J0 - Journal of Zhejiang University Science A
VL - 11
IS - 9
SP - 629
EP - 637
%@ 1673-565X
Y1 - 2010
PB - Zhejiang University Press & Springer
ER -
DOI - 10.1631/jzus.A1000095


Abstract: 
The use of a biotrickling filter was investigated for a pilot field-scale elimination of NH3 gas and other odorous gases from a composting plant in Tongzhou District, Beijing. The inlet gas flow rate was 3500 m3/h and NH3 concentration fluctuated between 2.76–27.84 mg/m3, while the average outlet concentration was 1.06 mg/m3 with an average of 94.9% removal. Critical volumetric loading (removal efficiency=100%) was 11.22 g-N/(m3·h). The odor concentration removal was 86.7%. NH3 removal efficiency decreased as the free ammonia (FA) in the trickling liquid increased. The pressure drop was maintained at about 50 Pa/m and was never more than 55 Pa/m. During the experiment, there was neither backflushing required nor any indication of clogging. Overall, the biotrickling filter was highly efficient and cost-effective for the simultaneous biodegradation of NH3 and other odorous gases from composting, suggesting the possibility of treating odorous gases at the industrial level.

Darkslateblue:Affiliate; Royal Blue:Author; Turquoise:Article

Reference

[1]Anthonisen, A.C., Loehr, R.C., Prakasam, T., Srinath, E.G., 1976. Inhibition of nitrification by ammonia and nitrous acid. Journal of Water Pollution Control Federation, 48(5):835-852.

[2]Chang, K., Lu, C., 2003. Biofiltration of isopropyl alcohol and acetone mixtures by a trickle-bed air biofilter. Process Biochemistry, 39(4):415-423.

[3]Chou, M., Huang, J., 1997. Treatment of methylethylketone in air stream by biotrickling filters. Journal of Environmental Engineering, 123(6):569-576.

[4]Chou, M., Wang, C., 2007. Treatment of ammonia in air stream by biotrickling filter. Aerosol and Air Quality Research, 7(1):17-32.

[5]Chung, Y., Lin, Y., Tseng, C., 2005. Removal of high concentration of NH3 and coexistent H2S by biological activated carbon (BAC) biotrickling filter. Bioresource Technology, 96(16):1812-1820.

[6]Cox, H.H.J., Deshusses, M.A., 1999. Biomass control in waste air biotrickling filters by protozoan predation. Biotechnology and Bioengineering, 62(2):216-224.

[7]Deshusses, M.A., Webster, T.S., 2000. Construction and economics of a pilot/full-scale biological trickling filter reactor for the removal of volatile organic compounds from polluted air. Journal of the Air & Waste Management Association, 50(11):1947-1956.

[8]Fortin, N.Y., Deshusses, M.A., 1999. Treatment of methyl tert-butyl ether vapors in biotrickling filters. 1. Reactor startup, steady-state performance, and culture characteristics. Environmental Science & Technology, 33(17):2980-2986.

[9]Fortuny, M., Baeza, J.A., Gamisans, X., Casas, C., Lafuente, J., Deshusses, M.A., Gabriel, D., 2008. Biological sweetening of energy gases mimics in biotrickling filters. Chemosphere, 71(1):10-17.

[10]Galera, M.M., Cho, E., Tuuguu, E., Park, S.J., Farnazo, D.M., Jee, C., Yoo, N.J., Chung, W.J., 2007. Removal of NH3, H2S and toluene by biofilters packed with rock wool-compost media. Journal of Industrial and Engineering Chemistry, 13(6):895-902.

[11]GB 14554-93. Emission Standards for Odor Pollutants. State Environmental Protection Administration of China (in Chinese).

[12]GB 7479-87. Water Quality—Determination of Ammonium—Nessler’s Reagent Colorimetric Method. State Environmental Protection Administration of China (in Chinese).

[13]GB 7493-87. Water Quality—Determination of Nitrogen (Nitrite)—Spectrophotometric Method. State Environmental Protection Administration of China (in Chinese).

[14]GBZ 2.1-2007. Occupational Exposure Limits for Hazardous Agents in the Workplace. Ministry of Health of China (in Chinese).

[15]HJ/T 346-2007. Water Quality—Determination of Nitrate-nitrogen—Ultraviolet Spectrophotometric Method. State Environmental Protection Administration of China (in Chinese).

[16]HJ/T 399-2007. Water Quality—Determination of the Chemical Oxygen Demand—Fast Digestion-spectrophotometric Method. State Environmental Protection Administration of China (in Chinese).

[17]Ho, K.L., Chung, Y.C., Tseng, C.P., 2008. Continuous deodorization and bacterial community analysis of a biofilter treating nitrogen-containing gases from swine waste storage pits. Bioresource Technology, 99(8):2757-2765.

[18]Iliuta, I., Iliuta, M.C., Larachi, F., 2005. Hydrodynamics modeling of bioclogging in waste gas treating trickle-bed bioreactors. Industrial & Engineering Chemistry Research, 44(14):5044-5052.

[19]Lu, C., Lin, M.R., Lin, J., 2001. Removal of styrene vapor from waste gases by a trickle-bed air biofilter. Journal of Hazardous Materials, 82(3):233-245.

[20]Mao, I.F., Tsai, C., Shen, S., Lin, T., Chen, W., Chen, M., 2006. Critical components of odors in evaluating the performance of food waste composting plants. Science of the Total Environment, 370(2-3):323-329.

[21]Mathur, A.K., Majumder, C.B., 2008. Biofiltration and kinetic aspects of a biotrickling filter for the removal of paint solvent mixture laden air stream. Journal of Hazardous Materials, 152(3):1027-1036.

[22]Nisola, G.M., Cho, E., Orata, J.D., Redillas, M.C.F.R., Farnazo, D.M.C., Tuuguu, E., Chung, W.J., 2009. NH3 gas absorption and bio-oxidation in a single bioscrubber system. Process Biochemistry, 44(2):161-167.

[23]Pagans, E., Font, X., Sánchez, A., 2005. Biofiltration for ammonia removal from composting exhaust gases. Chemical Engineering Journal, 113(2-3):105-110.

[24]Park, S., Bae, W., 2009. Modeling kinetics of ammonium oxidation and nitrite oxidation under simultaneous inhibition by free ammonia and free nitrous acid. Process Biochemistry, 44(6):631-640.

[25]Park, S.J., Nam, S.I., Choi, E.S., 2001. Removal of odor emitted from composting facilities using a porous ceramic biofilter. Water Science and Technology, 44(9):301-308.

[26]Ramirez, M., Gómez, J.M., Aroca, G., Cantero, D., 2009. Removal of ammonia by immobilized Nitrosomonas europaea in a biotrickling filter packed with polyurethane foam. Chemosphere, 74(10):1385-1390.

[27]Sakuma, T., Aoki, M., Hattori, T., Gabriel, D., Deshusses, M.A., 2004. A Conceptual Model for the Treatment of Ammonia Vapors in a Biotrickling Filter. Annual Meeting and Exhibition of the Air and Waste Management Association, Pittsburgh, PA. Indianapolis, IN, p.1-16.

[28]Sakuma, T., Jinsiriwanit, S., Hattori, T., Deshusses, M.A., 2008. Removal of ammonia from contaminated air in a biotrickling filter—Denitrifying bioreactor combination system. Water Research, 42(17):4507-4513.

[29]Sempere, F., Gabaldón, C., Martínez-Soria, V., Marzal, P., Penya-roja, J.M., Javier Álvarez-Hornos, F., 2008. Performance evaluation of a biotrickling filter treating a mixture of oxygenated VOCs during intermittent loading. Chemosphere, 73(9):1533-1539.

[30]Tian, S., Zhang, L., Wang, Q., Wang, X., Xie, W., 2007. Study on hydrogen sulfide removal based on bench-scale experiment by bio-trickling filter. Journal of Zhejiang University-SCIENCE A, 8(7):1141-1148.

[31]Tsang, Y.F., Chua, H., Sin, S.N., Chan, S.Y., 2008. Treatment of odorous volatile fatty acids using a biotrickling filter. Bioresource Technology, 99(3):589-595.

[32]Villaverde, S., Garcia-Encina, P.A., Fdz-Polanco, F., 1997. Influence of pH over nitrifying biofilm activity in submerged biofilters. Water Research, 31(5):1180-1186.

[33]Wang, Q., Zhang, L., Tian, S., Sun, P.T., Xie, W., 2007. A pilot-study on treatment of a waste gas containing butyl acetate, n-butyl alcohol and phenylacetic acid from pharmaceutical factory by bio-trickling filter. Biochemical Engineering Journal, 37(1):42-48.

[34]Yu, G., Xu, X., He, P., 2007. Isolates identification and characteristics of microorganisms in biotrickling filter and biofilter system treating H2S and NH3. Journal of Environmental Sciences, 19(7):859-863.

[35]Zhang, L., Wang, Q., Jiao, Z., Xie, W., Xia, B., 2008. Treatment of hydrogen sulfide odor by bio-trickling filter. Journal of Nanjing University of Science and Technology (Natural Science), 32(01):123-126 (in Chinese).

[36]Zhang, L., Meng, X., Wang, Y., Liu, L., 2009. Performance of biotrickling filters for hydrogen sulfide removal under starvation and shock loads conditions. Journal of Zhejiang University-SCIENCE B, 10(8):595-601.