Full Text:   <3887>

CLC number: TP393

On-line Access: 2024-08-27

Received: 2023-10-17

Revision Accepted: 2024-05-08

Crosschecked: 2013-09-16

Cited: 3

Clicked: 16370

Citations:  Bibtex RefMan EndNote GB/T7714

-   Go to

Article info.
Open peer comments

Journal of Zhejiang University SCIENCE C 2013 Vol.14 No.10 P.766-776

http://doi.org/10.1631/jzus.C1300084


IEEE 1588 based time synchronization system for a seafloor observatory network


Author(s):  De-jun Li, Gang Wang, Can-jun Yang, Bo Jin, Yan-hu Chen

Affiliation(s):  State Key Laboratory of Fluid Power Transmission and Control, Zhejiang University, Hangzhou 310027, China

Corresponding email(s):   li_dejun@zju.edu.cn, wgseu@126.com

Key Words:  Seafloor observatory network, Junction box, IEEE 1588, Time synchronization


De-jun Li, Gang Wang, Can-jun Yang, Bo Jin, Yan-hu Chen. IEEE 1588 based time synchronization system for a seafloor observatory network[J]. Journal of Zhejiang University Science C, 2013, 14(10): 766-776.

@article{title="IEEE 1588 based time synchronization system for a seafloor observatory network",
author="De-jun Li, Gang Wang, Can-jun Yang, Bo Jin, Yan-hu Chen",
journal="Journal of Zhejiang University Science C",
volume="14",
number="10",
pages="766-776",
year="2013",
publisher="Zhejiang University Press & Springer",
doi="10.1631/jzus.C1300084"
}

%0 Journal Article
%T IEEE 1588 based time synchronization system for a seafloor observatory network
%A De-jun Li
%A Gang Wang
%A Can-jun Yang
%A Bo Jin
%A Yan-hu Chen
%J Journal of Zhejiang University SCIENCE C
%V 14
%N 10
%P 766-776
%@ 1869-1951
%D 2013
%I Zhejiang University Press & Springer
%DOI 10.1631/jzus.C1300084

TY - JOUR
T1 - IEEE 1588 based time synchronization system for a seafloor observatory network
A1 - De-jun Li
A1 - Gang Wang
A1 - Can-jun Yang
A1 - Bo Jin
A1 - Yan-hu Chen
J0 - Journal of Zhejiang University Science C
VL - 14
IS - 10
SP - 766
EP - 776
%@ 1869-1951
Y1 - 2013
PB - Zhejiang University Press & Springer
ER -
DOI - 10.1631/jzus.C1300084


Abstract: 
An IEEE 1588 based application scheme was proposed to achieve accurate time synchronization for a deep seafloor observatory network based on the communication topological structure of the Zhejiang University Experimental and Research Observatory. The principles of the network time protocol (NTP) and precision time protocol (PTP) were analyzed. The framework for time synchronization of the shore station, undersea junction box layer, and submarine science instrument layer was designed. NTP and PTP network signals were decoded by a PTP master clock on a shore station that receives signals from the Global Positioning System and the BeiDou Navigation Satellite System as reference time sources. These signals were remotely transmitted by a subsea optical–electrical composite cable through an Ethernet passive optical network. Accurate time was determined by time synchronization devices in each layer. Synchronization monitoring experiments performed within a laboratory environment indicated that the proposed system is valid and has the potential to realize microsecond accuracy to satisfy the time synchronization requirements of a high-precision seafloor observatory network.

Darkslateblue:Affiliate; Royal Blue:Author; Turquoise:Article

Reference

[1]Carta, A., Locci, N., Muscas, C., Pinna, F., Sulis, S., 2011. GPS and IEEE 1588 synchronization for the measurement of synchrophasors in electric power systems. Comput. Stand. Interf., 33(2):176-181.

[2]Chen, Y.H., Yang, C.J., Li, D.J., Jin, B., Chen, Y., 2012a. Design and application of a junction box for cabled ocean observatories. Mar. Technol. Soc. J., 46(3):50-63.

[3]Chen, Y.H., Yang, C.J., Li, D.J., Jin, B., Chen, Y., 2012b. Development of a direct current power system for a multi-node cabled ocean observatory system. J. Zhejiang Univ.-Sci. C (Comput. & Electron.), 13(8):613-623.

[4]Chen, Y.H., Yang, C.J., Li, D.J., Jin, B., Chen, Y., 2013. Study on 10 kVDC powered junction box for a cabled ocean observatory system. China Ocean Eng., 27(2):265-275.

[5]del Rio, J., Toma, D., Shariat-Panahi, S., Mànuel, A., Ramos, H.G., 2012. Precision timing in ocean sensor systems. Meas. Sci. Technol., 23(2):025801.

[6]Du, Z.P., Lu, Y.M., Ji, Y.F., 2011. An enhanced end-to-end transparent clock mechanism with a fixed delay ratio. IEEE Commun. Lett., 15(8):872-874.

[7]Ferrari, P., Flammini, A., Marioli, D., Taroni, A., 2008. IEEE 1588-based synchronization system for a displacement sensor network. IEEE Trans. Instrum. Meas., 57(2):254-260.

[8]Ferrari, P., Flammini, A., Rinaldi, S., Bondavalli, A., Brancati, F., 2011. Evaluation of Timestamping Uncertainty in a Software-Based IEEE1588 Implementation. IEEE Conf. on Instrumentation and Measurement Technology, p.1-6.

[9]Han, J., Jeong, D.K., 2010. A practical implementation of IEEE 1588-2008 transparent clock for distributed measurement and control systems. IEEE Trans. Instrum. Meas., 59(2):433-439.

[10]Jin, S.G., 2013. Recent progresses on BeiDou/COMPASS and other global navigation satellite systems (GNSS)–I. Adv. Space Res., 51(6):941.

[11]Kanazawa, T., Shinohara, M., Sakai, S., Utada, H., Shiobara, H., Yamada, T., Mochizuki, K., 2011. New Innovative Ocean Bottom Cabled Seismometer System and Observation in the Sea of Japan. IEEE Int. Symp. on Scientific Use of Submarine Cables and Related Technologies, p.1-3.

[12]Lentz, S., Lécroart, A., 2009. Precision Timing in the NEPTUNE Canada Network. OCEANS, p.1-5.

[13]Li, D.J., Yang, J.C., Lin, D.D., Yang, C.J., Jin, B., 2012. Power monitor system in seafloor junction box based on MCU and CPLD. J. Zhejiang Univ. (Eng. Sci.), 46(8):1369-1374 (in Chinese).

[14]Li, Z.S., Li, D.J., Lin, L., Chen, Y., 2010. Design considerations for electromagnetic couplers in contactless power transmission systems for deep-sea applications. J. Zhejiang Univ.-Sci. C (Comput. & Electron.), 11(10):824-834.

[15]Lixia, M., Muscas, C., Sulis, S., 2009. Application of IEEE 1588 to the Measurement of Synchrophasors in Electric Power Systems. IEEE Int. Symp. on Precision Clock Synchronization for Measurement, Control and Communication, p.1-6.

[16]López, J.M., Ruiz, M., Borrego, J., de Arcas, G., Barrera, E., Vega, J., 2010. A versatile trigger and synchronization module with IEEE1588 capabilities and EPICS support. Fus. Eng. Des., 85(3-4):340-344.

[17]Loschmidt, P., Exel, R., Nagy, A., Gaderer, G., 2008. Limits of Synchronization Accuracy Using Hardware Support in IEEE 1588. IEEE Int. Symp. on Precision Clock Synchronization for Measurement, Control and Communication, p.12-16.

[18]Mànuel, A., Roset, X., del Rio, J., Mihai Toma, D., Carreras, N., Shariat Panahi, S., Garcia-Benadí, A., Owen, T., Cadena, J., 2012. Ocean bottom seismometer: design and test of a measurement system for marine seismology. Sensors, 12(12):3693-3719.

[19]Milevsky, A., Walrod, J., 2008. Development and Test of IEEE 1588 Precision Timing Protocol for Ocean Observatory Networks. OCEANS, p.1-7.

[20]Mills, D.L., 2003. A brief history of NTP time: memoirs of an Internet timekeeper. ACM SIGCOMM Comput. Commun. Rev., 33(2):9-21.

[21]Mills, D.L., Martin, J., Burbank, J., Kasch, W., 2010. Network Time Protocol (Version 4) - Protocol and Algorithms Specification. DARPA Network Working Group Report RFC-5905, University of Delaware. Available from http://www.rfc-editor.org/rfc/rfc5905.txt [Accessed on Mar. 23, 2013].

[22]Moreno-Muñoz, A., Pallarés-López, V., de la Rosa, J.J.G., Real-Calvo, R., González-Redondo, M., Moreno-García, I.M., 2013. Embedding synchronized measurement technology for smart grid development. IEEE Trans. Ind. Inf., 9(1):52-61.

[23]Neagoe, T., Cristea, V., Banica, L., 2006. NTP versus PTP in Computer Networks Clock Synchronization. IEEE Int. Symp. on Industrial Electronics, p.317-362.

[24]Ouellette, M., Ji, K., Liu, S., Li, H., 2011. Using IEEE 1588 and boundary clocks for clock synchronization in telecom networks. IEEE Commun. Mag., 49(2):164-171.

[25]Refan, M.H., Valizadeh, H., 2011. Redundant GPS Time Synchronization Boards for Computer Networks. 19th Telecommunications Forum, p.904-907.

[26]Sun, J., Ma, H.H., Xu, D., 2010. High Precision Time Synchronization Scheme for Distributed Intrusion Detection System. Int. Conf. on Computer Application and System Modeling, p.V2-219-V2-223.

[27]Wang, Y.W., Long, F., 2010. Research of Time Synchronization in Digital Substation Based on IEEE1588. 2nd Int. Conf. on Information Science and Engineering, p.2320-2325.

[28]Ye, S., 2011. Beidou time synchronization receiver for smart grid. Energy Proc., 12:37-42.

[29]Ying, G., 2012. Energy attenuation-based time synchronization for mobile underwater sensor networks. J. China Univ. Posts Telecommun., 19(2):57-64.

[30]Zhang, X.L., Tang, X.Q., Chen, J.H., 2008. Time synchronization of hierarchical real-time networked CNC system based on Ethernet/Internet. Adv. Manuf. Technol., 36(11-12):1145-1156.

Open peer comments: Debate/Discuss/Question/Opinion

<1>

Please provide your name, email address and a comment





Journal of Zhejiang University-SCIENCE, 38 Zheda Road, Hangzhou 310027, China
Tel: +86-571-87952783; E-mail: cjzhang@zju.edu.cn
Copyright © 2000 - 2024 Journal of Zhejiang University-SCIENCE