YAN Jian-hua, PENG Zheng, LU Sheng-yong, LI Xiao-dong, CEN Ke-fa. Removal of PCDDs/Fs from municipal solid waste incineration by entrained-flow adsorption technology[J]. Journal of Zhejiang University Science A, 2006, 7(11): 1896-1903.
@article{title="Removal of PCDDs/Fs from municipal solid waste incineration by entrained-flow adsorption technology",
author="YAN Jian-hua, PENG Zheng, LU Sheng-yong, LI Xiao-dong, CEN Ke-fa",
journal="Journal of Zhejiang University Science A",
volume="7",
number="11",
pages="1896-1903",
year="2006",
publisher="Zhejiang University Press & Springer",
doi="10.1631/jzus.2006.A1896"
}
%0 Journal Article
%T Removal of PCDDs/Fs from municipal solid waste incineration by entrained-flow adsorption technology
%A YAN Jian-hua
%A PENG Zheng
%A LU Sheng-yong
%A LI Xiao-dong
%A CEN Ke-fa
%J Journal of Zhejiang University SCIENCE A
%V 7
%N 11
%P 1896-1903
%@ 1673-565X
%D 2006
%I Zhejiang University Press & Springer
%DOI 10.1631/jzus.2006.A1896
TY - JOUR
T1 - Removal of PCDDs/Fs from municipal solid waste incineration by entrained-flow adsorption technology
A1 - YAN Jian-hua
A1 - PENG Zheng
A1 - LU Sheng-yong
A1 - LI Xiao-dong
A1 - CEN Ke-fa
J0 - Journal of Zhejiang University Science A
VL - 7
IS - 11
SP - 1896
EP - 1903
%@ 1673-565X
Y1 - 2006
PB - Zhejiang University Press & Springer
ER -
DOI - 10.1631/jzus.2006.A1896
Abstract: entrained flow adsorption using activated carbon as the adsorbent is widely adopted for PCDDs/Fs-abatement in municipal solid waste incineration (MSWI) process. The effects of operating parameters including flue gas temperature, feeding rate of activated carbon, polychlorinated dibenzodioxins and polychlorinated dibenzofurans (PCDDs/Fs) concentration at the inlet of the air pollution control device (APCD), filter materials, pressure drop on PCDDs/Fs removal efficiency are reviewed and commented upon in this paper. Evaluation on the various mechanistic models for entrained flow adsorption is carried out based on the computational simulation in terms of the actual operating condition and theoretical analysis. Finally, an advancement of entrained flow adsorption in combination of dual bag filter is introduced.
[1] Buekens, A., Huang, H., 1998. Comparative evaluation of techniques for controlling the formation the emission of chlorinated dioxins/furans in municipal waste incineration. J. Hazard. Mater., 62(1):1-33.
[2] Everaert, K., Baeyens, J., 2004. Removal of PCDD/F from flue gases in fixed or moving bed adsorbers. Waste Management, 24(1):37-42.
[3] Everaert, K., Baeyens, J., Degreve, J., 2003. Entrained-phase adsorption of PCDD/F from incinerator flue gases. Environ. Sci. Techno., 37(6):1219-1224.
[4] Kilgroe, J.D., 1996. Control of dioxin, furan and mercury emissions from municipal waste combustor. J. Hazard. Mater., 47(1-3):163-194.
[5] Kilgroe, J.D., Nelson, L.P., Schindler, P.J., Lanier, W.S., 1990. Combustion control of organic emissions from municipal. waste combustors. Combust. Sci. Tech., 74:223-244.
[6] Kilgroe, J.D., Lanier, W.S., VonAlten, T.R., 1992. Proc. National Waste Processing Conf., American Society of Mechanical Engineers. Book No. 100328, New York.
[7] Kim, B.H., Kim, J.H., 2004. Removal of PCDDs/Fs from a Solid Waste Incinerator Using a Dual Bag Filter System with Recycled Activated Carbon. Proceedings of the 3rd International Conference on Combustion, Incineration/ Pyrolysis and Emission Control, p.313-318.
[8] Lu, S.Y., 2004. The Dioxin Formation, Inhibition and Control Mechanisms from Coal and Waste Combustion. Ph.D Thesis, Zhejiang University, Hangzhou, p.126-129 (in Chinese).
[9] Mätzing, H., Baumann, W., Becker, B., 2001. Adsorption of PCDD/F of MWI fly ash. Chemosphere, 42(5-7):803-809.
[10] McKay, G., 2002. Dioxin characterization, formation and minimization during municipal solid waste (MSW) incineration: review. Chemical Engineering Journal, 86(3):343-368.
[11] Milligan, M.S., Altwicker, E.R., 1996. Chlorophenol reactions on fly ash. 2. equilibrium surface coverage and global kinetics. 3. Environ. Sci. Technol., 30(1):230-236.
[12] Shin, S., Choi, S., Oh, J.E., 1999. Evaluation of polychlorinated dibenzo-p-dioxin/dibenzofuran (PCDD/F) emission in municipal solid waste incinerators. Environ. Sci. Technol., 33(15):2657-2666.
[13] Smolka, A., 1997. Gas particle partitioning before and after flue gas purification by an activated carbon filter. Chemosphere, 34(5-7):1075-1082.
[14] Tejima, H., Nakagawa, I., Shinoda, T., Maeda, I., 1996. PCDDs/PCDFs reduction by good combustion technology and fabric filter with/without activated carbon injection. Chemosphere, 32(1):169-175.
[15] Weber, R., Takasuga, T., Nagai, K., 2002. Dechlorination and destruction of PCDD, PCDF and PCB on selected fly ash from municipal waste incineration. Chemosphere, 46(9-10):1255-1262.