CLC number: TM721
On-line Access: 2024-08-27
Received: 2023-10-17
Revision Accepted: 2024-05-08
Crosschecked: 2009-04-27
Cited: 4
Clicked: 6333
E. ABIRI, A. RAHMATI, A. ABRISHAMIFAR. A sensorless and simple controller for VSC based HVDC systems[J]. Journal of Zhejiang University Science A, 2009, 10(12): 1824-1834.
@article{title="A sensorless and simple controller for VSC based HVDC systems",
author="E. ABIRI, A. RAHMATI, A. ABRISHAMIFAR",
journal="Journal of Zhejiang University Science A",
volume="10",
number="12",
pages="1824-1834",
year="2009",
publisher="Zhejiang University Press & Springer",
doi="10.1631/jzus.A0820504"
}
%0 Journal Article
%T A sensorless and simple controller for VSC based HVDC systems
%A E. ABIRI
%A A. RAHMATI
%A A. ABRISHAMIFAR
%J Journal of Zhejiang University SCIENCE A
%V 10
%N 12
%P 1824-1834
%@ 1673-565X
%D 2009
%I Zhejiang University Press & Springer
%DOI 10.1631/jzus.A0820504
TY - JOUR
T1 - A sensorless and simple controller for VSC based HVDC systems
A1 - E. ABIRI
A1 - A. RAHMATI
A1 - A. ABRISHAMIFAR
J0 - Journal of Zhejiang University Science A
VL - 10
IS - 12
SP - 1824
EP - 1834
%@ 1673-565X
Y1 - 2009
PB - Zhejiang University Press & Springer
ER -
DOI - 10.1631/jzus.A0820504
Abstract: voltage source converter high-voltage direct current (VSC-HVDC) is a new power transmission technology preferable in small or medium power transmission. In this paper we discuss a new control system based on space vector modulation (SVM) without any voltage line sensors. Using direct power control (DPC) SVM and a new double synchronous reference frame phase-locked loop (DSRF-PLL) approach, the control system is resistant to the majority of line voltage disturbances. Also, the system response has accelerated by using a feed forward power decoupled loop. The operation of this control strategy was verified in a SIMULINK/MATLAB simulation environment. To validate this control system, a 5 kV·A prototype system was constructed. Compared to the original controllers, the current total harmonic distortion (THD), the active and reactive deviations and the DC voltage overshoot were lowered by 2.5%, 6.2% and 8%, respectively. The rectifier power factor in the worst condition was 0.93 and the DC voltage settling time was 0.2 s.
[1] Asplund, G., 2000. Application of HVDC Light to Power System Enhancement. IEEE Power Engineering Society Winter Meeting, 4:2498-2503.
[2] Asplund, G., Eriksson, K., Svensson, K., 1997. HVDC Light-DC Transmission Based on Voltage Sourced Converters. CIGRE SC14 Colloquium, p.1-8.
[3] Chen, Q., Tang, G., Hu, M., 2004. Steady-state model and controller design of a VSC-HVDC converter based on dq0-axis. Autom. Electr. Power Syst., 28(16):61-66.
[4] Cichowlas, M., Malinowski, M., Kazmierkowski, M.P., Sobczuk, D.L., Rodrigues, P., Pou, J., 2005. Active filtering function of three-phase PWM boost rectifier under different line voltage conditions. IEEE Trans. Ind. Electron., 52(2):410-419.
[5] Hu, Z.Q., Mao, C.X., Lu, J.M., 2004. Application of an optimal control strategy to a new type of HVDC system based on voltage source converters. Power Syst. Technol., 28(10):38-41.
[6] Hu, Z.Q., Mao, C.X., M., Lu J.M., Chen M., 2005. Genetic Algorithm Based Control for VSC HVDC. IEEE/PES Transmission and Distribution Conf. & Exhibition, p.1-5.
[7] Li, G.I., Ruan, S., Peng, L., Sun, Y., Li, X., 2005. A Novel Nonlinear Control for Stability Improvement in HVDC Light System. IEEE Power Engineering Society General Meeting, 1:837-845.
[8] Li, G.K., Li, G.Y., Yin, M., Zhou, C.Y., Liang, H.F., 2005. Research on Dynamic Mathematic Model of VSC-HVDC Based on Energy Conservation Principle. IEEE/PES Transmission and Distribution Conf. and Exhibition: Asia and Pacific, p.1-4.
[9] Li, G.Y., Lv, P.F., Li, G.K., Zhou, M., 2003. The development and prospect of the HVDC Light transmission technology. Autom. Electr. Power Syst., 27:77-81.
[10] Li, G.Y., Zhou, M., Yin, M., Zhou, C.Y., 2006. Modeling of VSC-HVDC and Control Strategies for Supplying Both Active and Passive Systems. IEEE Power Engineering Society General Meeting, p.1-6.
[11] Malinowski, M., Kazmierkowski, M.P., Hansen, S., Blaabjerg, F., Marques, G.D., 2001. Virtual flux based direct power control of three-phase PWM rectifiers. IEEE Trans. Ind. Appl., 37(4):1019-1027.
[12] Malinowski, M., Kazmierkowski, M.P., Jasinski, M., 2004. Simple direct power control of three-phase PWM rectifier using space-vector modulation (DPC-SVM). IEEE Trans. Ind. Electron., 51(2):447-454.
[13] Ooi, B.T., Wang, X., 1991. Boost-type PWM HVDC transmission system. IEEE Trans. Power Del., 6(4):1557-1563.
[14] Rahmati, A., Abrishamifar, A., Abiri, E., 2006. Direct Power Control of an HVDC System Based on VSCs. IEEE Int. Conf. on Industrial Technology, p.2984-2989.
[15] Rodriguez, P., Sainz, L., Bergas, J., 2002. Synchronous Double Reference Frame PLL Applied to a Unified Power Quality Conditioner. IEEE 10th Int. Conf. on Harmonics and Quality of Power, 2:614-619.
[16] Rodriguez, P., Bergas, J., Pou, J., Candela, I., Burgos, R., Boroyevich, D., 2005. Double Synchronous Reference Frame PLL for Power Converters Control. IEEE 36th Conf. on Power Electronic Specialists, p.1415-1421.
[17] Song, R., Zheng, C., Li, R., Zhou, X., 2005. VSCs Based HVDC and Its Control Strategy. IEEE/PES Transmission and Distribution Conf. and Exhibition: Asia and Pacific, p.1-6.
[18] Zhang, G.B., Xu, Z., 2001. Steady-state Model for VSC Based HVDC and Its Controller Design. IEEE Power Engineering Society Winter Meeting, 3:1085-1090.
[19] Zhang, G.B., Xu, Z., Wang, G.Z., 2002. Steady-state model and its nonlinear control of VSC-HVDC system. Proc. CSEE, 22(1):17-22 (in Chinese).
Open peer comments: Debate/Discuss/Question/Opinion
<1>