Journal of Zhejiang University SCIENCE A 2011 Vol.12 No.5 P.390-398

http://doi.org/10.1631/jzus.A1000304


Water quality improvement of a lagoon containing mixed chemical industrial wastewater by micro-electrolysis-contact oxidization


Author(s):  Ya-fei Zhou, Mao Liu, Qiong Wu

Affiliation(s):  College of Environmental Science and Engineering, Nankai University, Tianjin 300071, China; more

Corresponding email(s):   nkzhouyf@gmail.com

Key Words:  Memetic algorithm (MA), Neural network (NN) learning, Back propagation (BP), Extremal optimization (EO), Levenberg-Marquardt (LM) gradient search, Basic oxygen furnace (BOF)


Ya-fei Zhou, Mao Liu, Qiong Wu. Water quality improvement of a lagoon containing mixed chemical industrial wastewater by micro-electrolysis-contact oxidization[J]. Journal of Zhejiang University Science A, 2011, 12(5): 390-398.

@article{title="Water quality improvement of a lagoon containing mixed chemical industrial wastewater by micro-electrolysis-contact oxidization",
author="Ya-fei Zhou, Mao Liu, Qiong Wu",
journal="Journal of Zhejiang University Science A",
volume="12",
number="5",
pages="390-398",
year="2011",
publisher="Zhejiang University Press & Springer",
doi="10.1631/jzus.A1000304"
}

%0 Journal Article
%T Water quality improvement of a lagoon containing mixed chemical industrial wastewater by micro-electrolysis-contact oxidization
%A Ya-fei Zhou
%A Mao Liu
%A Qiong Wu
%J Journal of Zhejiang University SCIENCE A
%V 12
%N 5
%P 390-398
%@ 1673-565X
%D 2011
%I Zhejiang University Press & Springer
%DOI 10.1631/jzus.A1000304

TY - JOUR
T1 - Water quality improvement of a lagoon containing mixed chemical industrial wastewater by micro-electrolysis-contact oxidization
A1 - Ya-fei Zhou
A1 - Mao Liu
A1 - Qiong Wu
J0 - Journal of Zhejiang University Science A
VL - 12
IS - 5
SP - 390
EP - 398
%@ 1673-565X
Y1 - 2011
PB - Zhejiang University Press & Springer
ER -
DOI - 10.1631/jzus.A1000304


Abstract: 
A lagoon in the New Binhai District, a high-speed developing area, Tianjin, China, has long been receiving the mixed chemical industrial wastewater from a chemical industrial park. This lagoon contained complex hazardous substances such as heavy metals and accumulative pollutants which stayed over time with a poor biodegradability. According to the characteristics of wastewater in the lagoon, the micro-electrolysis process was applied to improve the biodegradability before the bioprocess treatment. By the orthogonal experimental study of main factors influencing the efficiency of the treatment method, the best control parameters were obtained, including pH=2.0, a volume ratio of Fe and reaction wastewater of 0.03750, a volume ratio of Fe and the granular activated carbon (GAC) of 2.0, a mixing speed of 200 r/min, and a hydraulic retention time (HRT) of 1.5 h. In the meantime, the removal rate of chemical oxygen demand (COD) was up to 64.6%, and NH4+–N and Pb in the influent were partly removed. After the micro-electrolysis process, the ratio of biochemical oxygen demand (BOD) to COD (B/C ratio) was greater than 0.6, thus providing a favorable basis for bioprocess treatment.

Darkslateblue:Affiliate; Royal Blue:Author; Turquoise:Article

Reference

[1]Acharya, C., Nakhla, G., Bassi, A., Kurian, R., 2004. Treatment of high strength pet food wastewater using two-stage membrane bioreactors. Water Environment Research, 78(7):661-670.

[2]Cheng, C.C., Hu, D.W., Zhou, J.X., 2005. Study on the process of dyestuff wastewater treated by microelectrolysis. Chemistry and Bioengineering, 22(1):29-30 (in Chinese).

[3]Cheng, H.F., Xu, W.P., Liu, J.L., Wang, H.J., He, Y.Q., Chen, G., 2007. Pretreatment of wastewater from triazine manufacturing by coagulation, electrolysis, and internal microelectrolysis. Journal of Hazardous Materials, 146(1-2):385-392.

[4]Chiang, L.C., Chang, J.E., Wen, T.C., 1995. Indirect oxidation effect in electrochemical oxidation treatment of landfill leachate. Water Research, 29(2):671-678.

[5]Dai, X.L., 2005. Study on the treatment of chromium- containing wastewater of galvanization by utilizing the technology of micro-electrolysis and its application. Industrial Water Treatment, 25(1):69-71 (in Chinese).

[6]Dhouib, A., Hamad, N., Hassairi, I., Sayadi, S., 2003. Degradation of anionic surfactants by Citrobacter braakii. Process Biochemistry, 38(8):1245-1250.

[7]Dhouib, A., Aloui, F., Hamad, N., Sayadi, S., 2006. Pilot-plant treatment of olive mill wastewaters by Phanerochaete chrysosporium coupled to anaerobic digestion and ultrafiltration. Process Biochemistry, 41(1):159-167.

[8]Ellouze, M., Saddoud, A., Dhouib, A., Sayadi, S., 2009. Assessment of the impact of excessive chemical additions to municipal wastewaters and comparison of three technologies in the removal performance of pathogens and toxicity. Microbiological Research, 164(2):138-148.

[9]Geng, Z., Hall, E.R., 2006. Characterization of fouled membranes from a membrane enhanced biological phosphorus removal system. Water Science & Technology, 54(10):169-176.

[10]Han, H.J., 1991. Industrial wastewater treatment by micro-electrolysis. Environmental Protection, 1:17-18 (in Chinese).

[11]Jin, Y.Z., Zhang, Y.F., Li, W., 2003. Micro-electrolysis technology for industrial wastewater treatment. Journal of Environmental Sciences, 15(3):334-338.

[12]Kurian, R., Nakhla, G., Bassi, A., 2006. Biodegradation kinetics of high strength oily pet food wastewater in a membrane-coupled bioreactor (MBR). Chemosphere, 65(7):1204-1211.

[13]Li, C., Xia, J., Wang, Y.Z., 2004. Micro-electrolysis process for treating dyeing wastewater. Journal of Nanjing Forestry University (Natural Sciences Edition), 28(1):87-88 (in Chinese).

[14]Li, D.S., Wang, B.S., 2003. Pretreatment of high concentration organic chemical wastewater by aerated Fe/C micro-electrolysis. China Water & Wastewater, 19(10):58-60 (in Chinese).

[15]Liu, G.X., Cheng, A.H., Wang, Z.Y., 2008. Research on enhanced biological nitrogen removal by micro-electrolysis method. Chinese Journal of Environmental Engineering, 2(7):927-931 (in Chinese).

[16]Lou, J.C., Huang, Y.J., Han, J.Y., 2009. Treatment of printed circuit board industrial wastewater by Ferrite process combined with Fenton method. Journal of Hazardous Materials, 170(2-3):620-626.

[17]Nghiem, L.D., Hawkes, S., 2007. Effects of membrane fouling on the nanofiltration of pharmaceutically active compounds (PhACs): mechanisms and role of membrane pore size. Separation and Purification Technology, 57(1):176-184.

[18]Pérez, M., Torrades, F., Domenech, X., Peral, J., 2002. Fenton and photo-Fenton oxidation of textile effluents. Water Research, 36(11):2703-2710.

[19]Ribordy, P., Pulgarin, C., Kiwi, J., Peringer, P., 1997. Electrochemical versus photochemical pretreatment of industrial wastewater. Water Science & Technology, 35(4):293-302.

[20]Scholz, W., Fuchs, W., 2000. Treatment of oil contaminated wastewater in a membrane bioreactor. Water Research, 34(4):3621-3629.

[21]State Environmental Protection Administration of China, 2002. Methods for the Examination of Water and Wastewater Analysis. China Environmental Science Press, Beijing, China (in Chinese).

[22]Wang, M.X., Zhu, S.Q., He, X.W., 2001. Study on micro-electrolysis treatment for decolorizing dyed water. Journal of China University of Mining & Technology, 11(2):212-216 (in Chinese).

[23]Wang, X.Q., Hu, X.M., Shen, X., 2008. Study on treatment for dyeing wastewater by iron-carbon micro-electrolysis and A/O process. Industrial Safety and Environmental Protection, 34(7):22-25 (in Chinese).

[24]Wu, H.F., Kong, H.L., Wang, S.H., 2003. Study on pretreatment of agricultural pesticide wastewater by micro-electrolytic method and Fenton reagent oxidation method. Techniques and Equipment for Environmental Pollution Control, 4(2):18-21 (in Chinese).

[25]Wu, Q., Zhou, Q.X., Hua, T., 2009. Development of micro-electrolysis and its combined process for refractory wastewater. Technology of water treatment, 35(11):27-32 (in Chinese).

[26]Xiao, T.T., Han, Y.H., Jin, D., Zhang, L., 2009. Removal of lead from PAC through micro-electrolysis. Liao Ning Chemical, 38(1):11-14 (in Chinese).

[27]Xu, D.H., Li, D.S., Wang, Z.P., 2003. Research on the treatment of coking plant wastewater by the process of aeration micro-electrolysis. Water Purification Technology, 19(10):58-60 (in Chinese).

[28]Yang, J., Lu, Z.Y., Hu, J.C., Gu, X.S., 1997. Status and prospects of technology for antibiotics industrial waste-water treatment. Environmental Science, 18(3):83-85 (in Chinese).

[29]Zakkour, P.D., Gaterell, M.R., Griffin, P., Gochin, R.J., Lester, J.N., 2001. Anaerobic treatment of domestic wastewater in temperate climates: treatment plant modeling with economic considerations. Water Research, 35(17):4137-4149.

[30]Zhou, G.P., Fu, D.F., 2001. Application and development for micro-electrolysis technology. Techniques and Equipment for Environmental Pollution Control, 2(4):18-24 (in Chinese).

[31]Zhu, X.B., Zhou, J.T., Qiu, J.S., 2004. A pilot-plant study of applying micro-electrolysis process to reuse of effluent from petroleum refinery. Environmental Engineering, 22(2):7-9 (in Chinese).

[32]Zhu, S., Hua, T., Zhou, Q.X., Wu, Q., 2009. Ecological safety regulation of A/DAT-IAT process for municipal wastewater treatment. Chinese Journal of Applied Ecology, 20(5):1209-1213 (in Chinese).

Open peer comments: Debate/Discuss/Question/Opinion

<1>

Please provide your name, email address and a comment





Journal of Zhejiang University-SCIENCE, 38 Zheda Road, Hangzhou 310027, China
Tel: +86-571-87952783; E-mail: cjzhang@zju.edu.cn
Copyright © 2000 - 2024 Journal of Zhejiang University-SCIENCE