Full Text:   <800>

CLC number: 

On-line Access: 2022-05-10

Received: 2022-04-05

Revision Accepted: 2022-04-12

Crosschecked: 2022-05-11

Cited: 0

Clicked: 845

Citations:  Bibtex RefMan EndNote GB/T7714

 ORCID:

Jin-yuan Qian

https://orcid.org/0000-0002-5438-0833

-   Go to

Article info.
Open peer comments

Journal of Zhejiang University SCIENCE A 2022 Vol.23 No.4 P.243-246

http://doi.org/10.1631/jzus.A22FCSV1


Practice of flow control and smart valves


Author(s):  Jin-yuan QIAN, Wei WU, Min CHENG, Jun-hui ZHANG

Affiliation(s):  Institute of Process Equipment, College of Energy Engineering, Zhejiang University, Hangzhou 310027, China; more

Corresponding email(s):   qianjy@zju.edu.cn, wuweijing@bit.edu.cn, chengmin@cqu.edu.cn

Key Words:  Flow control, Smart valve


Share this article to: More |Next Article >>>

Jin-yuan QIAN, Wei WU, Min CHENG, Jun-hui ZHANG. Practice of flow control and smart valves[J]. Journal of Zhejiang University Science A, 2022, 23(4): 243-246.

@article{title="Practice of flow control and smart valves",
author="Jin-yuan QIAN, Wei WU, Min CHENG, Jun-hui ZHANG",
journal="Journal of Zhejiang University Science A",
volume="23",
number="4",
pages="243-246",
year="2022",
publisher="Zhejiang University Press & Springer",
doi="10.1631/jzus.A22FCSV1"
}

%0 Journal Article
%T Practice of flow control and smart valves
%A Jin-yuan QIAN
%A Wei WU
%A Min CHENG
%A Jun-hui ZHANG
%J Journal of Zhejiang University SCIENCE A
%V 23
%N 4
%P 243-246
%@ 1673-565X
%D 2022
%I Zhejiang University Press & Springer
%DOI 10.1631/jzus.A22FCSV1

TY - JOUR
T1 - Practice of flow control and smart valves
A1 - Jin-yuan QIAN
A1 - Wei WU
A1 - Min CHENG
A1 - Jun-hui ZHANG
J0 - Journal of Zhejiang University Science A
VL - 23
IS - 4
SP - 243
EP - 246
%@ 1673-565X
Y1 - 2022
PB - Zhejiang University Press & Springer
ER -
DOI - 10.1631/jzus.A22FCSV1


Abstract: 
We believe this special issue will provide a forum for researchers and engineers to present and discuss recent developments in the practice of flow control and smart valves. We expect the selected papers will stimulate discussion among scientific researchers, and we hope that they will bring new inspiration to readers of this journal.

流动控制与智能阀门的实践

作者:钱锦远1,5,吴维2,程敏3,张军辉4,5
机构:1浙江大学,能源工程学院,化工机械研究所,中国杭州,310027;2北京理工大学,机械与车辆学院,中国北京,100081;3重庆大学,机械与运载工程学院,中国重庆,400044;4浙江大学,机械工程学院,机电控制技术与工程研究所,中国杭州,310027;5浙江大学,流体动力与机电系统国家重点实验室,中国杭州,310027
概要:工业互联网的不断发展对阀门的小型化、数字化、多功能性和系统化产生了更迫切的需求。值得注意的是,如果阀门工作在高温高压环境中,或在纳米流体、压缩氢和过热蒸汽等新型流体中,阀门流动的智能控制则显得尤为重要。开发精确度高、响应速度快、参数反馈准确、远程操作方便且具有故障在线即时诊断和故障安全保障等功能的智能泵阀迫在眉睫。为此,本专辑收集了在该研究领域具有代表性的研究成果,介绍了流动控制和智能阀门实践的最新发展,希望能帮助读者快速了解智能泵阀及其流动控制技术在各个领域中的应用,推动该领域的发展,并为智能泵阀的设计制造和流动控制的实现提供科学依据和技术支撑。

关键词:智能泵阀;流动控制;精确调节;故障诊断

Darkslateblue:Affiliate; Royal Blue:Author; Turquoise:Article

Reference

[1]BonillaCA, ZanfeiA, BrentanB, et al., 2022. A digital twin of a water distribution system by using graph convolutional networks for pump speed-based state estimation. Water, 14(4):514.

[2]ChangV, XuYK, ZhangJQ, et al., 2021. Research on intelligent manufacturing development approach for China’s local valve industry. Smart and Sustainable Built Environment, 10(2):293-321.

[3]di CapaciRB, ScaliC, 2018. Review and comparison of techniques of analysis of valve stiction: from modeling to smart diagnosis. Chemical Engineering Research and Design, 130:230-265.

[4]FiderekP, KucharskiJ, WajmanR, 2022. Fuzzy regulator for two-phase gas-liquid pipe flows control. Applied Sciences, 12(1):399.

[5]JiX, WangAC, WeiXH, 2021. Precision control of spraying quantity based on linear active disturbance rejection control method. Agriculture, 11(8):761.

[6]JinZJ, QiuC, JiangCH, et al., 2020. Effect of valve core shapes on cavitation flow through a sleeve regulating valve. Journal of Zhejiang University-SCIENCE A (Applied Physics & Engineering), 21(1):1-14.

[7]KangJ, YuanZH, LiJC, 2022. Mechanism analysis and evaluation of thermal effects on the operating point drift of servo valves. Journal of Zhejiang University-SCIENCE A (Applied Physics & Engineering), 23(4):286-302.

[8]LinZH, LiJY, JinZJ, et al., 2021. Fluid dynamic analysis of liquefied natural gas flow through a cryogenic ball valve in liquefied natural gas receiving stations. Energy, 226:120376.

[9]LinZH, YuLJ, HuaTF, et al., 2022. Seal contact performance analysis of soft seals on high-pressure hydrogen charge valves. Journal of Zhejiang University-SCIENCE A (Applied Physics & Engineering), 23(4):247-256.

[10]LuL, XuYP, LiMR, et al., 2022. Analysis of fretting wear behavior of unloading valve of gasoline direct injection high-pressure pump. Journal of Zhejiang University-SCIENCE A (Applied Physics & Engineering), 23(4):314-328.

[11]LyuF, YeSG, ZhangJH, et al., 2021. Theoretical and simulation investigations on flow ripple reduction of axial piston pumps using nonuniform distribution of pistons. Journal of Dynamic Systems, Measurement, and Control, 143(4):041008.

[12]LyuLT, ChenZ, YaoB, 2021. Advanced valves and pump coordinated hydraulic control design to simultaneously achieve high accuracy and high efficiency. IEEE Transactions on Control Systems Technology, 29(1):236-248.

[13]MaoZB, AsaiY, WiranataA, et al., 2022. Eccentric actuator driven by stacked electrohydrodynamic pumps. Journal of Zhejiang University-SCIENCE A (Applied Physics & Engineering), 23(4):329-334.

[14]PangJH, ZhangN, XiaoQ, et al., 2021. A new intelligent and data-driven product quality control system of industrial valve manufacturing process in CPS. Computer Communications, 175:25-34.

[15]PedersenHC, Bak-JensenT, JessenRH, et al., 2022. Temperature-independent fault detection of solenoid-actuated proportional valve. IEEE/ASME Transactions on Mechatronics, in press.

[16]PengL, HanGQ, PagouAL, 2022. Real-time anomaly detection methodology in the electric submersible pump systems. Petroleum Science and Technology, in press.

[17]QianJY, WuJY, GaoZX, et al., 2020a. Effects of throttling window on flow rate through feed-water valves. ISA Transactions, 104:393-405.

[18]QianJY, HouCW, MuJ, et al., 2020b. Valve core shapes analysis on flux through control valves in nuclear power plants. Nuclear Engineering and Technology, 52(10):2173-2182.

[19]ShiJC, RenY, TangHS, et al., 2022. Hydraulic directional valve fault diagnosis using a weighted adaptive fusion of multi-dimensional features of a multi-sensor. Journal of Zhejiang University-SCIENCE A (Applied Physics & Engineering), 23(4):257-271.

[20]SiQR, LuR, ShenCH, et al., 2020. An intelligent CFD-based optimization system for fluid machinery: automotive electronic pump case application. Applied Sciences, 10(1):366.

[21]SunF, XuH, ZhaoYH, et al., 2022. Data-driven fault diagnosis of control valve with missing data based on modeling and deep residual shrinkage network. Journal of Zhejiang University-SCIENCE A (Applied Physics & Engineering), 23(4):303-313.

[22]TangHB, YangWX, WangZC, 2019. A model-based method for leakage detection of piston pump under variable load condition. IEEE Access, 7:99771-99781.

[23]VailatiLG, GoldfarbM, 2021. A method for mass flow and displacement estimation in a pneumatic actuation system using valve-based pressure sensing. IEEE/ASME Transactions on Mechatronics, 26(1):235-245.

[24]YuH, LiHR, LiYL, 2020. Vibration signal fusion using improved empirical wavelet transform and variance contribution rate for weak fault detection of hydraulic pumps. ISA Transactions, 107:385-401.

[25]YuanCG, PlummerA, PanM, 2022. Switching characteristics of a high-speed rotary valve for switched inertance hydraulic converters. Proceedings of the Institution of Mechanical Engineers, Part I: Journal of Systems and Control Engineering, in press.

[26]ZhangF, ZhangJH, ChengM, et al., 2022. A flow-limited rate control scheme for the master-slave hydraulic manipulator. IEEE Transactions on Industrial Electronics, 69(5):4988-4998.

[27]ZhaoKP, HeT, WangCL, et al., 2022. Lubrication characteristics analysis of slipper pair of digital valve distribution axial piston pump. Advances in Mechanical Engineering, 14(3):1-15.

[28]ZhongQ, XuEG, JiaTW, et al., 2022. Dynamic performance and control accuracy of a novel proportional valve with a switching technology-controlled pilot stage. Journal of Zhejiang University-SCIENCE A (Applied Physics & Engineering), 23(4):272-285.

[29]ZhouCJ, MaJ, WuJD, 2018. Fault diagnosis of check valve based on CEEMD compound screening, BSE and FCM. IFAC-Papersonline, 51(21):323-328.

Open peer comments: Debate/Discuss/Question/Opinion

<1>

Please provide your name, email address and a comment





Journal of Zhejiang University-SCIENCE, 38 Zheda Road, Hangzhou 310027, China
Tel: +86-571-87952783; E-mail: cjzhang@zju.edu.cn
Copyright © 2000 - 2024 Journal of Zhejiang University-SCIENCE