An approach to the capsule endoscopic robot with active drive motion


Author(s):  Da-qiang Gu, Yong Zhou

Affiliation(s):  Department of Mechanical Engineering, Zhejiang University, Hangzhou 310027, China

Corresponding email(s):   gudq@zju.edu.cn

Key Words:  Capsular endoscopy, Shape memory alloy (SMA), Microactuation, Locomotion


Da-qiang Gu, Yong Zhou. An approach to the capsule endoscopic robot with active drive motion[J]. Journal of Zhejiang University Science A, 2011, 12(3): 223-231.

@article{title="An approach to the capsule endoscopic robot with active drive motion",
author="Da-qiang Gu, Yong Zhou",
journal="Journal of Zhejiang University Science A",
volume="12",
number="3",
pages="223-231",
year="2011",
publisher="Zhejiang University Press & Springer",
doi="10.1631/jzus.A1000141"
}

%0 Journal Article
%T An approach to the capsule endoscopic robot with active drive motion
%A Da-qiang Gu
%A Yong Zhou
%J Journal of Zhejiang University SCIENCE A
%V 12
%N 3
%P 223-231
%@ 1673-565X
%D 2011
%I Zhejiang University Press & Springer
%DOI 10.1631/jzus.A1000141

TY - JOUR
T1 - An approach to the capsule endoscopic robot with active drive motion
A1 - Da-qiang Gu
A1 - Yong Zhou
J0 - Journal of Zhejiang University Science A
VL - 12
IS - 3
SP - 223
EP - 231
%@ 1673-565X
Y1 - 2011
PB - Zhejiang University Press & Springer
ER -
DOI - 10.1631/jzus.A1000141


Abstract: 
Commercialized capsule-type endoscopes move passively by peristaltic waves (and gravity), which makes it difficult for doctors to diagnose the areas of interest more thoroughly and actively. To resolve this problem of passivity, it is necessary to find a special locomotion principle, which fits the gastrointestinal (GI) tract. In this paper, a legged locomotive mechanism with shape memory alloy (SMA) actuation based on the peristaltic principle is proposed, and then the structure of the locomotion mechanism is introduced. Based on the preliminary results, the design, modeling, and fabrication of an SMA microactuation concept for application in an endoscopic capsule are given, as well as the SMA spring and legged component design, which is the core section of the system design. We used the pseudo-rigid-body model (PRBM) to analyze nonlinear and large deflections of the SMA legged component. Thus, a prototype endoscope with an SMA spring and six legged components was designed and fabricated. It is 15 mm in diameter and 33 mm in total length, with a hollow space to house other parts needed for endoscopy such as a camera, a radio frequency (RF) module, and sensors. During testing, the locomotive mechanism was effective in a plastic tube environment.

Darkslateblue:Affiliate; Royal Blue:Author; Turquoise:Article

Reference

[1]Appleyard, M., Fireman, Z., Glukhovsky, A., Jacob, H., Shreiver, R., Kadirkamanathan, S., Lavy, A., Lewkowicz, S., Scapa, E., Shofti, R., et al., 2000. A randomized trial comparing wireless capsule endoscopy with push enteroscopy for the detection of small-bowel lesions. Gastroenterology, 119(6):1431-1438.

[2]Cheung, E., Karagozler, M.E., Park, S., Kim, B., Sitti, M., 2005. A New Endoscopic Microcapsule Robot Using Beetle Inspired Microfibrillar Adhesives. IEEE/ASME International Conference on Advanced Intelligent Mechatronics, Monterey, CA, USA, p.551-557.

[3]Gorini, S., Quirini, M., Menciassi, A., Pernorio, G., Stefanini, C., Dario, P., 2006. A Novel SMA-Based Actuator for a Legged Endoscopic Capsule. The First IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics, Pisa, Italy, p.443-449.

[4]Howell, L.L., Midha, A., 1995. Parametric deflection approximations for end-loaded, large-deflection beams in compliant mechanisms. Journal of Mechanical Design, 117(1):156-165.

[5]Kim, B., Lee, S., Park, J.H., Park, J., 2004. Inchworm-Like Microrobot for Capsule Endoscope. IEEE International Conference on Robotics and Biomimetics, Shenyang, China, p.458-463.

[6]Kim, B., Lee, S., Park, J.H., Park, J., 2005a. Design and fabrication of a locomotive mechanism for capsule-type endoscopes using shape memory alloys (SMAs). IEEE/ ASME Transactions on Mechatronics, 10(1):77-86.

[7]Kim, B., Park, S., Jee, C.Y., Yoon, S., 2005b. An Earthworm-Like Locomotive Mechanism for Capsule Endoscopes. IEEE/RSJ International Conference on Intelligent Robots and Systems, Edmonton, AB, Canada, p.2997-3002.

[8]Li, W.D., Guo, W., Li, M.T., Zhu, Y.H., 2006. Design and Test of a Capsule Type Endoscope Robot with Novel Locomation Principle. The 9th International Conference on Control, Automation, Robotics and Vision, Singapore, p.1-6.

[9]Mattson, C.A., Howell, L.L., Magleby, S.P., 2004. Development of commercially viable compliant mechanisms using the pseudo-rigid-body model: case studies of parallel mechanisms. Journal of Intelligent Material Systems and Structures, 15:195-202.

[10]Menciassi, A., Stefanini, C., Gorini, S., Pernorio, G., Kim, B., Park, J.O., Dario, P., 2004. Locomotion of a Legged Capsule in the Gastrointestinal Tract: Theoretical Study and Preliminary Technological Results. 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, San Francisco, CA, USA, p.2767-2770.

[11]Moglia, A., Menciassi, A., Schurr, M.O., Dario, P., 2007. Wireless capsule endoscopy: from diagnostic devices to multipurpose robotic systems. Biomed Microdevices, 9(2):235-243.

[12]Moon, Y., Lee, J., Park, H., Lee, J., Ryu, J., Woo, S., Kim, M., Won, C., Kim, T., Cho, J., et al., 2007. Fabrication of the wireless systems for controlling movements of the electrical stimulus capsule in the small intestines. IEICE Transactions on Information and Systems, E90-D(2):586-593.

[13]Park, H., Park, S., Yoon, E., Kim, B., Park, J., Park, S., 2007. Paddling Based Microrobot for Capsule Endoscopes. IEEE International Conference on Robotics and Automation, Roma, Italy, p.3377-3382.

[14]Quirini, M., Scapellato, S., Valdastri, P., 2007. An Approach to Capsular Endoscopy with Active Motion. 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Lyon, France, p.2827-2830.

[15]Rogers, C.L.C.A., 1997. Design of shape memory alloy springs with applications in vibration control. Journal of Intelligent Material Systems and Structures, 8:314-322.

[16]Sendoh, M., Ishiyama, K., Arai, K.I., 2003. Fabrication of magnetic actuator for use in a capsule endoscope. IEEE Transactions on Magnetics, 39(5):3232-3234.

[17]Yang, J., Wu, Y.H., 1993. Shape Memory Alloy and Its Applications. University of Science and Technology of China Press, Hefei, China, p.208-209 (in Chinese).

[18]Zabulis, X., Sfakiotakis, M., Tsakiris, D.P., 2008. Effects of Vibratory Actuation on Endoscopic Capsule Vision. 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Vancouver, British Columbia, Canada, p.5901-5904.

[19]Zhou, Y.S., Li, L.X., Zhao, D.F., 2001. New kind of micro-robot. Chinese Journal of Mechanical Engineering, 37(1):11-13 (in Chinese).