Journal of Zhejiang University SCIENCE B 2006 Vol.7 No.9 P.745-748

http://doi.org/10.1631/jzus.2006.B0745


Surveillance of viral contamination of invasive medical instruments in dentistry


Author(s):  ZHOU Lin­,fu, ZHU Hai-hong, LIN Jun, HU Min­,jun, CHEN Feng, CHEN Zhi

Affiliation(s):  Experimental Center of Molecular and Cellular Biology, School of Medicine, Zhejiang University, Hangzhou 310006, China; more

Corresponding email(s):   chenzhi@zju.edu.cn

Key Words:  Glutaraldehyde, Viral contamination, Invasive


ZHOU Lin­fu, ZHU Hai-hong, LIN Jun, HU Min­jun, CHEN Feng, CHEN Zhi. Surveillance of viral contamination of invasive medical instruments in dentistry[J]. Journal of Zhejiang University Science B, 2006, 7(9): 745-748.

@article{title="Surveillance of viral contamination of invasive medical instruments in dentistry",
author="ZHOU Lin­fu, ZHU Hai-hong, LIN Jun, HU Min­jun, CHEN Feng, CHEN Zhi",
journal="Journal of Zhejiang University Science B",
volume="7",
number="9",
pages="745-748",
year="2006",
publisher="Zhejiang University Press & Springer",
doi="10.1631/jzus.2006.B0745"
}

%0 Journal Article
%T Surveillance of viral contamination of invasive medical instruments in dentistry
%A ZHOU Lin­
%A fu
%A ZHU Hai-hong
%A LIN Jun
%A HU Min­
%A jun
%A CHEN Feng
%A CHEN Zhi
%J Journal of Zhejiang University SCIENCE B
%V 7
%N 9
%P 745-748
%@ 1673-1581
%D 2006
%I Zhejiang University Press & Springer
%DOI 10.1631/jzus.2006.B0745

TY - JOUR
T1 - Surveillance of viral contamination of invasive medical instruments in dentistry
A1 - ZHOU Lin­
A1 - fu
A1 - ZHU Hai-hong
A1 - LIN Jun
A1 - HU Min­
A1 - jun
A1 - CHEN Feng
A1 - CHEN Zhi
J0 - Journal of Zhejiang University Science B
VL - 7
IS - 9
SP - 745
EP - 748
%@ 1673-1581
Y1 - 2006
PB - Zhejiang University Press & Springer
ER -
DOI - 10.1631/jzus.2006.B0745


Abstract: 
Objective: To investigate the viral contamination of invasive medical instruments in dentistry and to provide health administrative institutions with surveillance data. Methods: Sterilized samples were randomly collected from the department of dentistry to detect HBV-DNA, HCV-RNA, HIV-RNA and HBsAg. Results: Of the invasive medical instruments that were sterilized with 2% glutaraldehyde, one of the samples was positive for HBV-DNA, and another sample was positive for HBsAg. Conclusion: Though massive virus contamination of invasive medical instruments in dentistry has been reduced to a low level, the occurrence of contamination still remains.

Darkslateblue:Affiliate; Royal Blue:Author; Turquoise:Article

Reference

[1] Dai, Q., Xu, Z., Deng, X.H., Ding, L., 2004. Experimental study on effectiveness of sterilization of glutaraldehyde on dental handpieces. Beijing Oral. Medicine, 12(4):188-190 (in Chinese).

[2] Garcia, R., Barnard, B., Kennedy, V., 2000. The fifth evolutionary era in infection control: interventional epidemiology. Am. J. Infect. Control, 28(1):30-43.

[3] Hanson, P.J.V., Gor, D., Jeffries, D.J., 1990. Elimination of high titre HIV from fibreoptic endoscopes. Gut., 31:657-659.

[4] Heermann, K.H., Seitz, H., Thomssen, R., 1996. Capture and RT-PCR of hepatitis C virus RNA with safety primers. Journal of Virological Methods, 59(1-2):33-43.

[5] Hu, Y., 2002. Observation on disinfection of glutaraldehyde oral instruments. Journal of Pediatric Pharmacy, 8(2):63-64 (in Chinese).

[6] Hu, Y.W., Balaskas, E., Furione, M., Yen, P.H., Kessler, G., Scalia, V., Chui, L., Sher, G., 2000. Comparison and application of a novel genotyping method, semiautomated primer-specific and mispair extension analysis, and four other genotyping assays for detection of hepatitis C virus mixed-genotype infections. J. Clin. Microbiol., 38(8):2807-2813.

[7] Nedjar, S., Biswas, R.M., Hewlett, I.K., 1991. Co-amplification of specific sequences of HCV and HIV-1 genomes by using the polymerase chain reaction assay: a potential tool for the simultaneous detection of HCV and HCV-1. Journal of Virological Methods, 35(3):297-304.

[8] Wang, T.Y., Kuo, H.T., Chen, L.C., Chen, Y.T., Lin, C.N., Lee, M.M., 2002. Use of polymerase chain reaction for early detection and management of hepatitis C virus infection after needlestick injury. Ann. Clin. Lab. Sci., 32(2):137-141.

[9] Zhang, X.Q., 2004. Surveillance of HBsAg pollution of endoscope and instruments in stomatology clinic. Chin. J. Infect. Control, 3(3):271-272 (in Chinese).

[10] Zhou, J.P., Xu, H.Q., 2003. Measures against hepatitis B virus contamination in stomatology clinic. World Journal of Infection, 3(6):545 (in Chinese).

[11] Zhou, D.P., Yang, Z.P., Tong, W.B., Fu, Y.L., 2000. A preliminary study of viral cross-transmission in dentistry. Chin. J. Stomatol., 35(4):283-285 (in Chinese).

Open peer comments: Debate/Discuss/Question/Opinion

<1>

Please provide your name, email address and a comment





Journal of Zhejiang University-SCIENCE, 38 Zheda Road, Hangzhou 310027, China
Tel: +86-571-87952783; E-mail: cjzhang@zju.edu.cn
Copyright © 2000 - 2024 Journal of Zhejiang University-SCIENCE