Full Text:   <3497>

CLC number: O424

On-line Access: 2024-08-27

Received: 2023-10-17

Revision Accepted: 2024-05-08

Crosschecked: 0000-00-00

Cited: 2

Clicked: 6778

Citations:  Bibtex RefMan EndNote GB/T7714

-   Go to

Article info.
Open peer comments

Journal of Zhejiang University SCIENCE A 2008 Vol.9 No.1 P.79-87

http://doi.org/10.1631/jzus.A071340


Impact of load impedance on the performance of a thermoacoustic system employing acoustic pressure amplifier


Author(s):  Ke TANG, Zhong-jie HUANG, Tao JIN, Guo-bang CHEN

Affiliation(s):  Institute of Refrigeration and Cryogenics, Zhejiang University, Hangzhou 310027, China

Corresponding email(s):   ktang@zju.edu.cn, jintao@zju.edu.cn

Key Words:  Thermoacoustic engine, Acoustic pressure amplifier (APA), Thermoacoustics


Ke TANG, Zhong-jie HUANG, Tao JIN, Guo-bang CHEN. Impact of load impedance on the performance of a thermoacoustic system employing acoustic pressure amplifier[J]. Journal of Zhejiang University Science A, 2008, 9(1): 79-87.

@article{title="Impact of load impedance on the performance of a thermoacoustic system employing acoustic pressure amplifier",
author="Ke TANG, Zhong-jie HUANG, Tao JIN, Guo-bang CHEN",
journal="Journal of Zhejiang University Science A",
volume="9",
number="1",
pages="79-87",
year="2008",
publisher="Zhejiang University Press & Springer",
doi="10.1631/jzus.A071340"
}

%0 Journal Article
%T Impact of load impedance on the performance of a thermoacoustic system employing acoustic pressure amplifier
%A Ke TANG
%A Zhong-jie HUANG
%A Tao JIN
%A Guo-bang CHEN
%J Journal of Zhejiang University SCIENCE A
%V 9
%N 1
%P 79-87
%@ 1673-565X
%D 2008
%I Zhejiang University Press & Springer
%DOI 10.1631/jzus.A071340

TY - JOUR
T1 - Impact of load impedance on the performance of a thermoacoustic system employing acoustic pressure amplifier
A1 - Ke TANG
A1 - Zhong-jie HUANG
A1 - Tao JIN
A1 - Guo-bang CHEN
J0 - Journal of Zhejiang University Science A
VL - 9
IS - 1
SP - 79
EP - 87
%@ 1673-565X
Y1 - 2008
PB - Zhejiang University Press & Springer
ER -
DOI - 10.1631/jzus.A071340


Abstract: 
An acoustic pressure amplifier (APA) is capable of improving the match between a thermoacoustic engine and a load by elevating pressure ratio and acoustic power output. A standing-wave thermoacoustic engine driving a resistance-and-compliance (RC) load through an APA was simulated with linear thermoacoustics to study the impact of load impedance on the performance of the thermoacoustic system. Based on the simulation results, analysis focuses on the distribution of pressure amplitude and velocity amplitude in APA with an RC load of diverse acoustic resistances and compliance impedances. Variation of operating parameters, including pressure ratio, acoustic power, hot end temperature of stack, etc., versus impedance of the RC load is presented and analyzed according to the abovementioned distribution. A verifying experiment has been performed, which indicates that the simulation can roughly predict the system operation in the fundamental-frequency mode.

Darkslateblue:Affiliate; Royal Blue:Author; Turquoise:Article

Reference

[1] Arman, B., Wollan, J.J., Swift, G.W., Backhaus, S., 2003. Thermoacoustic Natural Gas Liquefiers and Recent Developments. Cryogenics and Refrigeration, Proceedings of ICCR’2003, p.123-127.

[2] Bao, R., Chen, G.B., Tang, K., Cao, W.H., Jin, T., 2006a. Thermoacoustically driven pulse tube refrigeration below 80 K by introducing an acoustic pressure amplifier. Applied Physics Letters, 89(21):211915.

[3] Bao, R., Chen, G.B., Tang, K., Jia, Z.Z., Cao, W.H., 2006b. Effect of RC load on performance of thermoacoustic engine. Cryogenics, 46(9):666-671.

[4] Dai, W., Luo, E.C., Hu, J.Y., Chen, Y.Y., 2005. A novel coupling configuration for thermoacoustically-driven pulse tube coolers: Acoustic amplifier. Chinese Science Bulletin, 50(18):2112-2114.

[5] Duthil, P., Baltean Carlès, D., Bétrancourt, A., François, M.X., Yu, Z.B., Thermeau, J.P., 2006. Experiments and valve modeling in thermoacoustic device. Advances in Cryogenic Engineering, 51(B):1095-1102.

[6] Hu, J.Y., Luo, E.C., Dai, W., Zhou, Y., 2007. A heat-driven thermoacoustic cryocooler capable of reaching below liquid hydrogen temperature. Chinese Science Bulletin, 52(4):574-576.

[7] Matsubara, Y., Dai, W., Onishi, T., Kushino, A., Sugita, H., 2003. Thermally Actuated Pressure Wave Generators for Pulse Tube Cooler. Cryogenics and Refrigeration, Proceedings of ICCR’2003, p.57-60.

[8] Nguyen, C.T., Yeckley, A.J., Schieb, D.J., Haberbusch, M.S., 2004. Hydrogen/oxygen propellant densifier thermoacoustic Stirling heat engine. Advances in Cryogenic Engineering, 49(B):1703-1709.

[9] Swift, G.W., 2002. Thermoacoustics: A Unifying Perspective for Some Engines and Refrigerators. Acoustical Society of America Publications, Sewickley, PA.

[10] Tang, K., Chen, G.B., Kong, B., 2004. A 115 K thermoacoustically driven pulse tube refrigerator with low onset temperature. Cryogenics, 44(5):287-291.

[11] Tang, K., Chen, G.B., Jin, T., Bao, R., Kong, B., Qiu, L.M., 2005. Influence of resonance tube length on performance of thermoacoustically driven pulse tube refrigerator. Cryogenics, 45(3):185-191.

[12] Tang, K., Chen, G.B., Jin, T., Bao, R., Li, X.M., 2006. Performance comparison of thermoacoustic engines with constant-diameter resonant tube and tapered resonant tube. Cryogenics, 46(10):699-704.

[13] Tang, K., Bao, R., Chen, G.B., Qiu, Y., Shou, L., Huang, Z.J., Jin, T., 2007. Thermoacoustically driven pulse tube cooler below 60 K. Cryogenics, 47(9-10):526-529.

[14] Yu, G.Y., Luo, E.C., Dai, W., Wu, Z.H., 2007. An energy-focused thermoacoustic-Stirling heat engine reaching a high pressure ratio of 1.40. Cryogenics, 47(2):132-134.

Open peer comments: Debate/Discuss/Question/Opinion

<1>

Please provide your name, email address and a comment





Journal of Zhejiang University-SCIENCE, 38 Zheda Road, Hangzhou 310027, China
Tel: +86-571-87952783; E-mail: cjzhang@zju.edu.cn
Copyright © 2000 - 2024 Journal of Zhejiang University-SCIENCE