Full Text:   <3080>

CLC number: TH137

On-line Access: 2024-08-27

Received: 2023-10-17

Revision Accepted: 2024-05-08

Crosschecked: 2011-03-17

Cited: 0

Clicked: 7534

Citations:  Bibtex RefMan EndNote GB/T7714

-   Go to

Article info.
Open peer comments

Journal of Zhejiang University SCIENCE A 2011 Vol.12 No.4 P.301-309

http://doi.org/10.1631/jzus.A1000405


Output speed and flow of double-acting double-stator multi-pumps and multi-motors


Author(s):  De-sheng Wen, Zhi-li Wang, Jun Gao, Yong Zhang, Shi-jun Lv, Tetsuhiro Tsukiji

Affiliation(s):  College of Mechanical Engineering, Yanshan University, Qinhuangdao 066004, China, College of Engineering and Applied Science, Sophia University, Tokyo 102-8554, Japan

Corresponding email(s):   Chily666@163.com

Key Words:  Multi-pumps, Multi-motors, Flow rate, Rotational speed, Hydraulic transmission, Differential motor


De-sheng Wen, Zhi-li Wang, Jun Gao, Yong Zhang, Shi-jun Lv, Tetsuhiro Tsukiji. Output speed and flow of double-acting double-stator multi-pumps and multi-motors[J]. Journal of Zhejiang University Science A, 2011, 12(4): 301-309.

@article{title="Output speed and flow of double-acting double-stator multi-pumps and multi-motors",
author="De-sheng Wen, Zhi-li Wang, Jun Gao, Yong Zhang, Shi-jun Lv, Tetsuhiro Tsukiji",
journal="Journal of Zhejiang University Science A",
volume="12",
number="4",
pages="301-309",
year="2011",
publisher="Zhejiang University Press & Springer",
doi="10.1631/jzus.A1000405"
}

%0 Journal Article
%T Output speed and flow of double-acting double-stator multi-pumps and multi-motors
%A De-sheng Wen
%A Zhi-li Wang
%A Jun Gao
%A Yong Zhang
%A Shi-jun Lv
%A Tetsuhiro Tsukiji
%J Journal of Zhejiang University SCIENCE A
%V 12
%N 4
%P 301-309
%@ 1673-565X
%D 2011
%I Zhejiang University Press & Springer
%DOI 10.1631/jzus.A1000405

TY - JOUR
T1 - Output speed and flow of double-acting double-stator multi-pumps and multi-motors
A1 - De-sheng Wen
A1 - Zhi-li Wang
A1 - Jun Gao
A1 - Yong Zhang
A1 - Shi-jun Lv
A1 - Tetsuhiro Tsukiji
J0 - Journal of Zhejiang University Science A
VL - 12
IS - 4
SP - 301
EP - 309
%@ 1673-565X
Y1 - 2011
PB - Zhejiang University Press & Springer
ER -
DOI - 10.1631/jzus.A1000405


Abstract: 
The primary focus of this study was to investigate a series of novel motors and pumps, based on a new type of structure called double-stator. The double-stator structure can be used as pump or motor just based on the application requirements. A certain amount of pumps or motors can be formed in one shell, and these sub-pumps or sub-motors can work alone or be combined without influence on each other. So this kind of double-stator pump (motor) is called a multi-pump (multi-motor). Through the analysis of multifarious connection modes of the double-acting double-stator multi-pumps and multi-motors, the mathematical expressions of the output flow rate and the rotational speed are acquired. The results indicate that a quantity of different flow rates can be provided by one fixed-displacement multi-pump under the condition of unalterable driven speed by electromotor. Likewise, when supplied by settled input flow, without complex variable mechanism, the functions of double-speed, multiple-speed, and even differential connection can be obtained by employing the use of a double-stator multi-motor. The novel hydraulic transmission is made of such a double-stator multi-pump and multi-motor, and has broad application prospects.

Darkslateblue:Affiliate; Royal Blue:Author; Turquoise:Article

Reference

[1]Azadeh, A., Ebrahimipour, V., Bavar, P., 2009. A fuzzy inference system for pump failure diagnosis to improve maintenance process: the case of a petrochemical industry. Expert Systems with Applications, 37(1):627-639.

[2]Bobzin, K., Lugscheidera, E., Maesa, M., Goldb, P.W., Loosb, J., Kuhnb, M., 2004. High-performance chromium aluminium nitride PVD-coatings on roller bearings. Surface & Coatings Technology, 188-189:649-654.

[3]Chawla, V., Prakash., S., Sidhu, B.S., 2007. State of the art: applications of mechanically alloyed nanomaterials—a review. Materials and Manufacturing Processes, 22(4):469-473.

[4]Jahns, T.M., Owen, E.L., 2001. AC adjustable-speed drives at the millennium: how did we get here? IEEE Transactions on Power Electronics, 16(1):17-25.

[5]Lei, T.J., 1998. New Compilation of Hydraulic Engineering Manual. Beijing Institute of Technology Press, Beijing, China, p.313-318 (in Chinese).

[6]Lin, T.L., Wang, Q.F., Hu, B.Z., Gong, W., 2010. Research on the energy regeneration systems for hybrid hydraulic excavators. Automation in Construction, 19(8):1016-1026.

[7]Ma, J.N., Fang, Y.T., Xu, B., Yang, H.Y., 2010. Optimization of cross angle based on the pumping dynamics model. Journal of Zhejiang University-SCIENCE A (Applied Physics & Engineering), 11(3):181-190.

[8]Manring, N.D., 2003. Valve-plate design for an axial piston pump operating at low displacements. Journal of Mechanical Design, 125(1):200-205.

[9]Nilsson, D., Prakash, B., 2009. Investigation into the seizure of hydraulic motors. Tribology International, 43(1-2):92-99.

[10]Peng, T.H., Xu, B., Yang, H.Y., 2004. Development and research overview on variable frequency hydraulic technology. Journal of Zhejiang University (Engineering Science), 38(2):215-221 (in Chinese).

[11]Shin, S.J., Sung, H.J., 2010. Three-dimensional simulation of a valveless pump. International Journal of Heat and Fluid Flow, 31(5):942-951.

[12]Spence, R., Amaral-Teixeira, J., 2009. A CFD parametric study of geometrical variations on the pressure pulsations and performance characteristics of a centrifugal pump. Computers & Fluids, 38(6):1243-1257.

[13]Wang, Y.Q., Zhang, W., 2003. Summary of fluid power transmission and control technology. Chinese Journal of Mechanical Engineering, 39(10):95-99 (in Chinese).

[14]Wang, W., Yang, H.Y., Zou, J., Ruan, X.D., Fu, X., 2009. Optimal design of Stewart platforms based on expanding the control bandwidth while considering the hydraulic system design. Journal of Zhejiang University-SCIENCE A, 10(1):22-30.

[15]Wen, D.S., 2003a. Double-Stator Torque Pump/Motor. China Patent 02144407.2 (in Chinese).

[16]Wen, D.S., 2003b. Quantitative Same Width and Curvilinear Double-Stators Pump. China Patent 02144406.4 (in Chinese).

[17]Wen, D.S., 2008. Quantitative Same Width and Curvilinear Double-Stators Axial Pump with Sliders. China Patent 200710139642.X (in Chinese).

[18]Wen, D.S., 2009. Innovation and Application for Hydraulic Component. Aviation Industry Press, Beijing, China, p.375-384 (in Chinese).

[19]Wen, D.S., 2011. Theoretical analysis of output speed of multi-pump and multi-motor driving system. Science China Technological Sciences, 54(4):992-997.

[20]Wen, D.S., Lu, S.J., Liu, X.C., Cai, X.Z., 2008. Theoretic research on variable displacement of equal-width double-stators pump and motor. Journal of Harbin Institute of Technology, 40(11):1840-1844 (in Chinese).

[21]Wen, D.S., Zhang, Y., Wang, Z.L., Lu, S.J., Tsukiji, T., 2011. Rotating speed and torque of triple-acting multi-pump and multi-motor. Journal of Xi’an Jiaotong University, 45(3): 81-84 (in Chinese).

[22]Xue, Z.F., Shi, L., 2010. Modeling and experimental investigation of a variable speed drive water source heat pump. Tsinghua Science and Technology, 15(4):434-440.

[23]Yang, H.Y., Ma, J.N., Xu, B., 2009. Research status of axial piston pump fluid—borne noise. Journal of Mechanical Engineering, 45(8):71-79.

[24]Yang, Z.W., Xu, B., Zhang, B., 2010. Study on control performance of digital piston pump based on virtual prototype technology. Journal of Zhejiang University (Engineering Science), 44(1):1-7 (in Chinese).

[25]Zhang, B., Xu, B., Xia, C.L., Yang, H.Y., 2009. Modeling and simulation on axial piston pump based on virtual prototype technology. Chinese Journal of Mechanical Engineering, 22(1):84-90.

Open peer comments: Debate/Discuss/Question/Opinion

<1>

Please provide your name, email address and a comment





Journal of Zhejiang University-SCIENCE, 38 Zheda Road, Hangzhou 310027, China
Tel: +86-571-87952783; E-mail: cjzhang@zju.edu.cn
Copyright © 2000 - 2024 Journal of Zhejiang University-SCIENCE