Full Text:   <2901>

CLC number: R57; TN99

On-line Access: 2024-08-27

Received: 2023-10-17

Revision Accepted: 2024-05-08

Crosschecked: 0000-00-00

Cited: 6

Clicked: 5759

Citations:  Bibtex RefMan EndNote GB/T7714

-   Go to

Article info.
Open peer comments

Journal of Zhejiang University SCIENCE B 2008 Vol.9 No.9 P.734-738

http://doi.org/10.1631/jzus.B0820099


Modeling of human colonic blood flow for a novel artificial anal sphincter system


Author(s):  Peng ZAN, Guo-zheng YAN, Hua LIU

Affiliation(s):  School of Electronics, Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai 200240, China

Corresponding email(s):   zanpeng@sjtu.edu.cn

Key Words:  Incontinence, Artificial anal sphincter, Colonic blood flow, Tissue ischemia


Peng ZAN, Guo-zheng YAN, Hua LIU. Modeling of human colonic blood flow for a novel artificial anal sphincter system[J]. Journal of Zhejiang University Science B, 2008, 9(9): 734-738.

@article{title="Modeling of human colonic blood flow for a novel artificial anal sphincter system",
author="Peng ZAN, Guo-zheng YAN, Hua LIU",
journal="Journal of Zhejiang University Science B",
volume="9",
number="9",
pages="734-738",
year="2008",
publisher="Zhejiang University Press & Springer",
doi="10.1631/jzus.B0820099"
}

%0 Journal Article
%T Modeling of human colonic blood flow for a novel artificial anal sphincter system
%A Peng ZAN
%A Guo-zheng YAN
%A Hua LIU
%J Journal of Zhejiang University SCIENCE B
%V 9
%N 9
%P 734-738
%@ 1673-1581
%D 2008
%I Zhejiang University Press & Springer
%DOI 10.1631/jzus.B0820099

TY - JOUR
T1 - Modeling of human colonic blood flow for a novel artificial anal sphincter system
A1 - Peng ZAN
A1 - Guo-zheng YAN
A1 - Hua LIU
J0 - Journal of Zhejiang University Science B
VL - 9
IS - 9
SP - 734
EP - 738
%@ 1673-1581
Y1 - 2008
PB - Zhejiang University Press & Springer
ER -
DOI - 10.1631/jzus.B0820099


Abstract: 
A novel artificial anal sphincter system has been developed to simulate the normal physiology of the human anorectum. With the goal of engineering a safe and reliable device, the model of human colonic blood flow has been built and the relationship between the colonic blood flow rate and the operating occlusion pressure of the anorectum is achieved. The tissue ischemia is analyzed based on constitutive relations for human anorectum. The results suggest that at the planned operating occlusion pressure of less than 4 kPa the artificial anal sphincter should not risk the vascularity of the human colon.

Darkslateblue:Affiliate; Royal Blue:Author; Turquoise:Article

Reference

[1] Bisset, A.F., 2004. Artificial anal sphincter for faecal incontinence. Steer, 4(3):7.

[2] Hajivassiliou, C.A., Carter, K.B., Finlay, I.G., 1997a. Biomechanical evaluation of an artificial anal sphincter prothesis. Journal of Medical Engineering & Technology, 21(3-4):89-95.

[3] Hajivassiliou, C.A., Carter, K.B., Finlay, I.G., 1997b. Assessment of a novel implantable artificial anal sphincter. Diseases of the Colon & Rectum, 40(6):711-717.

[4] Kloner, R.A., 1988. Introduction to the role of oxygen radicals in myocardial ischemia and infarction. Free Radical Biology and Medicine, 4(1):5-7.

[5] O'Brien, P., Skinner, S., 2000. Restoring control: the acticon neosphincter artificial bowel sphincter in the treatment of anal incontinence. Diseases of the Colon & Rectum, 43(9):1213-1216.

[6] Ortiz, H., Armendariz, P., DeMiguel, M., Ruiz, M.D., Alós, R., Roig, J.V., 2002. Complications and functional outcome following artificial anal sphincter implantation. British Journal of Surgery, 89(7):877-881.

[7] Patrício, J., Bernades, A., Nuno, D., Falcâo, F., Silveira, L., 1988. Surgical anatomy of the arterial blood-supply of the human rectum. Surgical and Radiologic Anatomy, 10(1):71-75.

[8] Rothbarth, J., Bemelman, W.A., Meijerink, W.J.H.J., Stiggelbout, A.M., Zwinderman, A.H., Buyze-Westerweel, M.E., Delemarre, J.B.V.M., 2001. What is the impact of fecal incontinence on quality of life. Diseases of the Colon & Rectum, 44(1):67-71.

[9] Satava, R.M., King, G.E., 1989. An artificial anal sphincter. Phase 2: implantable sphincter with a perineal colostomy. Journal of Surgical Research, 46(3):207-211.

[10] Shoshany, G., Pena, A., 1994. Evaluation of a silastic anorectal sphincter placed by the posterior sagittal approach in pigs. International Journal of Pediatric Surgical Science, 8:67-69.

[11] Sofia, C.A., Rush, B.F., Koziol, J., Rocko, J.M., Seebode, J.J., 1988. Experiences with an artificial sphincter to establish continence in dogs. The American Surgeon, 54:390-394.

[12] Tang, K., Huang, Z.J., Jin, T., Bao, R., Chen, G.B., 2007. Influence of input acoustic power on regenerator’s performance. Journal of Zhejiang University SCIENCE A, 8(9):1452-1456.

[13] Uozaki, Y., Dihmis, W.C., Yamauchi, H., Moczar, M., Miyama, M., Pasteau, F., Tixier, D., Bambang, S.L., Loisance, D.Y., 2001. Intestinal tissue oxygenation and tumor necrosis factor-α release during systemic blood flow changes in pigs with left ventricular assist devices. Artificial Organs., 25(1):53-57.

[14] Yan, G.Z., Zan, P., Ye, D.D., Liu, H., 2007. Design of Transcutaneous Energy Transmission System for Artificial Anal Sphincter. The 2007 IEEE International Conference on Mechatronics and Automation. Harbin, China, August 5-9, p.1434-1438.

Open peer comments: Debate/Discuss/Question/Opinion

<1>

Please provide your name, email address and a comment





Journal of Zhejiang University-SCIENCE, 38 Zheda Road, Hangzhou 310027, China
Tel: +86-571-87952783; E-mail: cjzhang@zju.edu.cn
Copyright © 2000 - 2024 Journal of Zhejiang University-SCIENCE