Frontiers of Information Technology & Electronic Engineering  2015 Vol.16 No.10 P.892-898

http://doi.org/10.1631/FITEE.1500135


Performance analysis for a two-way relaying power line network with analog network coding


Author(s):  Yu-wen Qian, Meng Tian, Xue Jiang, Hua-ju Song, Feng Shu, Jun Li

Affiliation(s):  School of Electronic and Optical Engineering, Nanjing University of Science and Technology, Nanjing 210094, China; more

Corresponding email(s):   admon1999@163.com

Key Words:  Power line communication, Outage probability, Symbol error rate, Signal attenuation


Share this article to: More <<< Previous Article|

Yu-wen Qian, Meng Tian, Xue Jiang, Hua-ju Song, Feng Shu, Jun Li. Performance analysis for a two-way relaying power line network with analog network coding[J]. Frontiers of Information Technology & Electronic Engineering, 2015, 16(10): 892-898.

@article{title="Performance analysis for a two-way relaying power line network with analog network coding",
author="Yu-wen Qian, Meng Tian, Xue Jiang, Hua-ju Song, Feng Shu, Jun Li",
journal="Frontiers of Information Technology & Electronic Engineering",
volume="16",
number="10",
pages="892-898",
year="2015",
publisher="Zhejiang University Press & Springer",
doi="10.1631/FITEE.1500135"
}

%0 Journal Article
%T Performance analysis for a two-way relaying power line network with analog network coding
%A Yu-wen Qian
%A Meng Tian
%A Xue Jiang
%A Hua-ju Song
%A Feng Shu
%A Jun Li
%J Frontiers of Information Technology & Electronic Engineering
%V 16
%N 10
%P 892-898
%@ 2095-9184
%D 2015
%I Zhejiang University Press & Springer
%DOI 10.1631/FITEE.1500135

TY - JOUR
T1 - Performance analysis for a two-way relaying power line network with analog network coding
A1 - Yu-wen Qian
A1 - Meng Tian
A1 - Xue Jiang
A1 - Hua-ju Song
A1 - Feng Shu
A1 - Jun Li
J0 - Frontiers of Information Technology & Electronic Engineering
VL - 16
IS - 10
SP - 892
EP - 898
%@ 2095-9184
Y1 - 2015
PB - Zhejiang University Press & Springer
ER -
DOI - 10.1631/FITEE.1500135


Abstract: 
In this paper, we investigate a two-way relaying power line communication (PLC) network with analog network coding. We focus on the analysis of the system outage probability, symbol error rate, and average capacity. Specifically, we first derive the probability density function (PDF) of the received signal-to-noise ratio (SNR) with a closed form, by exploiting the statistical properties of the PLC channel. Then with the help of this PDF, we develop the outage probability, symbol error rate, and average capacity with closed forms, based on the Hermite polynomial. Simulations show that the derived analytical results are consistent with those by Monte Carlo simulation.

This work is an interesting analysis on the use of TW AF relaying strategy on PLC.

电力线通信网络中具有网络编码功能的双向中继系统的性能分析

目的:面向具有深度衰落的电力线通信信道,分析具有网络编码功能的双向电力线中继系统的中断概率、误符号率以及平均信道容量。
创新点:在电力线通信网络中使用一种两阶段的中继通协议,从而可以使用网络编码技术提高通信效率,并使用Hermite多项式推导出系统的性能指标。
方法:首先,考虑电力线通信信道与传统信道的不同,针对具有脉冲噪声的电力线信道,建立具有编码功能的中继系统的系统模型(图1)。然后,针对建立的模型,分析接收端信噪比的表达式。应用电力线信道幅值的概率分布函数,推导接收端信噪比的概率分布函数。应用Hermite多项式推导出具有网络编码功能的双向中继系统的中断概率、误符号率以及平均系统容量。最后,根据实际的电力线系统建立仿真环境,在该环境中使用蒙特卡洛方法对推导的结果进行验证。仿真结果证明了推导的正确性。
结论:针对具有深度衰落的电力线信道,提出一种可靠的具有网络编码功能的双向中继通信系统,提高系统的通信效率与通信可靠性。推导该系统中中断概率、无符号率以及平均系统容量的闭合式,仿真结果证明其正确性。

关键词:电力线通信;中断概率;误符号率;信号衰落

Darkslateblue:Affiliate; Royal Blue:Author; Turquoise:Article

Reference

[1]Abramowitz, M., Stegun, I.A., 1970. Handbook of Mathematical Functions with Formulas, Graphs, and Mathematical Tables (9th Ed.). Dover Publications, New York.

[2]Balakirsky, V.B., Han Vinck, A.J., 2005. Potential performance of PLC systems composed of several communication links. Proc. IEEE Int. Symp. on Power Line Communications and Its Applications, p.6-8.

[3]Bumiller, G., Lampe, L., Hrasnica, H., 2010. Power line communication networks for large-scale control and automation systems. IEEE Commun. Mag., 48(4):106-113.

[4]Cheng, X.L., Cao, R., Yang, L.Q., 2013. Relay-aided amplify-and-forward powerline communications. IEEE Trans. Smart Grid, 4(1):265-272.

[5]Dubey, A., Mallik, R.K., Schober, R., 2014. Performance analysis of a power line communication system employing selection combining in correlated log-normal channels and impulsive noise. IET Commun., 8(7):1072-1082.

[6]Güzelgöz, S., Celebi, H.B., Arslan, H., 2011. Statistical characterization of the paths in multipath PLC channels. IEEE Trans. Power Deliv., 26(1):707-712.

[7]Kuhn, M., Berger, S., Wittneben, I.H., et al., 2010. Power line enhanced cooperative wireless communications. IEEE J. Sel. Areas Commun., 24(7):1401-1410.

[8]Lampe, L., Han Vinck, A.J., 2011. On cooperative coding for narrow band PLC networks. AEU Int. J. Electron. Commun., 65(8):681-687.

[9]Lampe, L., Schober, R., Yiu, S., 2006. Distributed space-time coding for multihop transmission in power line communication networks. IEEE J. Sel. Areas Commun., 24(7):1389-1400.

[10]McKay, M.R., Grant, A.J., Collings, I.B., 2007. Performance analysis of MIMO-MRC in double-correlated Rayleigh environments. IEEE Trans. Commun., 55(3):497-507.

[11]Popovski, P., Yomo, H., 2007. Physical network coding in two-way wireless relay channels. Proc. IEEE Int. Conf. on Communications, p.707-712.

[12]Tan, B., Thompson, J., 2011. Relay transmission protocols for in-door powerline communications networks. Proc. IEEE Int. Conf. on Communicatons Workshops, p.1-5.

[13]Tonello, A.M., Versolatto, F., D’Alessandro, S., 2010. Opportunistic relaying in in-home PLC networks. Proc. IEEE Global Telecommunications Conf., p.1-5.

[14]Zou, H., Chowdhery, A., Jagannathan, S., et al., 2009. Multi-user joint subchannel and power resource-allocation for powerline relay networks. Proc. IEEE Int. Conf. on Communications, p.443-449.