http://doi.org/10.1631/jzus.C0910757


Modeling and noise analysis of a fence structure micromachined capacitive accelerometer system


Author(s):  Xia Zhang, Hao Wang, Xu-dong Zheng, Shi-chang Hu, Zhong-he Jin

Affiliation(s):  Department of Information Science and Electronic Engineering, Zhejiang University, Hangzhou 310027, China, Beijing Institute of Aerospace Control Devices, Beijing 100854, China

Corresponding email(s):   d05zhangxia@zju.edu.cn

Key Words:  Capacitive accelerometer, Micro-electromechanical system (MEMS), Noise, Modeling, Simulation


Xia Zhang, Hao Wang, Xu-dong Zheng, Shi-chang Hu, Zhong-he Jin. Modeling and noise analysis of a fence structure micromachined capacitive accelerometer system[J]. Journal of Zhejiang University Science C, 2010, 11(12): 1009-1015.

@article{title="Modeling and noise analysis of a fence structure micromachined capacitive accelerometer system",
author="Xia Zhang, Hao Wang, Xu-dong Zheng, Shi-chang Hu, Zhong-he Jin",
journal="Journal of Zhejiang University Science C",
volume="11",
number="12",
pages="1009-1015",
year="2010",
publisher="Zhejiang University Press & Springer",
doi="10.1631/jzus.C0910757"
}

%0 Journal Article
%T Modeling and noise analysis of a fence structure micromachined capacitive accelerometer system
%A Xia Zhang
%A Hao Wang
%A Xu-dong Zheng
%A Shi-chang Hu
%A Zhong-he Jin
%J Journal of Zhejiang University SCIENCE C
%V 11
%N 12
%P 1009-1015
%@ 1869-1951
%D 2010
%I Zhejiang University Press & Springer
%DOI 10.1631/jzus.C0910757

TY - JOUR
T1 - Modeling and noise analysis of a fence structure micromachined capacitive accelerometer system
A1 - Xia Zhang
A1 - Hao Wang
A1 - Xu-dong Zheng
A1 - Shi-chang Hu
A1 - Zhong-he Jin
J0 - Journal of Zhejiang University Science C
VL - 11
IS - 12
SP - 1009
EP - 1015
%@ 1869-1951
Y1 - 2010
PB - Zhejiang University Press & Springer
ER -
DOI - 10.1631/jzus.C0910757


Abstract: 
We analyze the effects of possible noise sources on a fence structure micromachined capacitive accelerometer system by modeling and simulation to improve its performance. simulation results show that a mismatch between the two initial sensing capacitors of the accelerometer or a mismatch between the two capacitance-voltage conversion circuits has a great effect on the output noise floor. When there is a serious mismatch, the noise induced by a sinusoidal carrier is the major noise source. When there is no or only a slight mismatch, the differential capacitance-voltage conversion circuits become the main noise source. The simulation results were validated by experiments and some effective approaches are proposed to improve the system resolution.

Darkslateblue:Affiliate; Royal Blue:Author; Turquoise:Article

Reference

[1]Beeby, S., Ensell, G., Kraft, M., Neil, W., 2004. MEMS Mechanical Sensors. Artech House, Boston, USA, p.39-56.

[2]Clark, W.A., 1997. Micromachined Vibratory Rate Gyroscopes. PhD Thesis, University of California, Berkeley, USA, p.101-104.

[3]Couch, L.W., 1983. Digital and Analog Communication Systems. Prentice Hall, Inc., New Jersey, USA, p.416-594.

[4]Gopel, W., Hesse, J., Zemel, J., 1994. Sensors: a Comprehensive Survey, Vol. 7, Mechanical Sensors. Wiley-VCH, Wienheim.

[5]Izham, Z., Ward, M.C.L., 2004. Dynamic simulation of a resonant MEMS magnetometer in Simulink. Sens. Actuat. A, 115(2-3):392-400.

[6]Kulah, H., Najafi, K., 2002. A Low Noise Switched-Capacitor Interface Circuit for Sub-micro Gravity Resolution Micromachined Accelerometers. Proc. ESSCIRC, p.635-638.

[7]Leland, R.P., 2005. Mechanical-thermal noise in MEMS gyroscopes. IEEE Sens. J., 5(3):493-500.

[8]Lewis, C.P., Kraft, M., 1996. Simulation of a Micromachined Digital Accelerometer in Simulink and PSPICE. UKACC Int. Conf. on Control, p.205-209.

[9]Mohite, S., Patil, N., Pratap, R., 2006. Design, modeling and simulation of vibratory micromachined gyroscopes. J. Phys., 34:757-763.

[10]Peitgen, H., Saupe, D., 1982. The Science of Fractal Images. Springer-Verlag, New York, USA, p.93-94.

[11]Petkov, V.P., Boser, B.E., 2004. Capacitive Interfaces for MEMS. In: Baltes, H., Brand, O., Fedder, G.K., et al. (Eds.), Advanced Micro and Nanosystems. Wiley-VCH, Weinheim, p.49-92.

[12]Wu, J., Fedder, G.K., Carley, L.R., 2004. A low-noise low-offset capacitive sensing amplifier for a 50µg/√Hz monolithic CMOS MEMS accelerometer. IEEE J. Sol.-State Circ., 39(5):722-730.

[13]Xue, W., Wang, J., Cui, T., 2005. Modeling and design of polymer-based tunneling accelerometers by ANSYS/MATLAB. IEEE/ASME Trans. Mechatr., 10(4):468-472.

[14]Yazdi, N., Ayazi, F., Najafi, K., 1998. Micromachined inertial sensors. Proc. IEEE, 86(8):1640-1659.

[15]Yun, W., 1992. A Surface Micromachined Accelerometer with Integrated CMOS Detection Circuitry. PhD Thesis, University of California, Berkeley, USA.

[16]Zhang, X., Zheng, X.D., Zheng, Y.M., Luo, S.J., Wang, Y.L., Jin, Z.H., 2008. A new modeling method of MEMS system’s noise. Chin. J. Sens. Actuat., 21(3):498-500 (in Chinese).

[17]Zheng, X.D., Jin, Z.H., Wang, Y.L., Lin, W.J., Zhou, X.Q., 2009. An in-plane low-noise accelerometer fabricated with an improved process flow. J. Zhejiang Univ.-Sci. A, 10(10):1413-1420.

Open peer comments: Debate/Discuss/Question/Opinion