Full Text:   <3781>

CLC number: TP293

On-line Access: 2024-08-27

Received: 2023-10-17

Revision Accepted: 2024-05-08

Crosschecked: 2013-05-17

Cited: 3

Clicked: 7919

Citations:  Bibtex RefMan EndNote GB/T7714

-   Go to

Article info.
Open peer comments

Journal of Zhejiang University SCIENCE C 2013 Vol.14 No.6 P.433-448

http://doi.org/10.1631/jzus.C1200363


Improving the real-time performance of Ethernet for plant automation (EPA) based industrial networks


Author(s):  Li Lu, Dong-qin Feng, Jian Chu

Affiliation(s):  Institute of Cyber-Systems and Control, Zhejiang University, Hangzhou 310027, China; more

Corresponding email(s):   llu@iipc.zju.edu.cn, dqfeng@iipc.zju.edu.cn

Key Words:  Ethernet for plant automation (EPA), Fast real-time (FRT) system, Real-time Ethernet (RTE), Scheduling scheme


Li Lu, Dong-qin Feng, Jian Chu. Improving the real-time performance of Ethernet for plant automation (EPA) based industrial networks[J]. Journal of Zhejiang University Science C, 2013, 14(6): 433-448.

@article{title="Improving the real-time performance of Ethernet for plant automation (EPA) based industrial networks",
author="Li Lu, Dong-qin Feng, Jian Chu",
journal="Journal of Zhejiang University Science C",
volume="14",
number="6",
pages="433-448",
year="2013",
publisher="Zhejiang University Press & Springer",
doi="10.1631/jzus.C1200363"
}

%0 Journal Article
%T Improving the real-time performance of Ethernet for plant automation (EPA) based industrial networks
%A Li Lu
%A Dong-qin Feng
%A Jian Chu
%J Journal of Zhejiang University SCIENCE C
%V 14
%N 6
%P 433-448
%@ 1869-1951
%D 2013
%I Zhejiang University Press & Springer
%DOI 10.1631/jzus.C1200363

TY - JOUR
T1 - Improving the real-time performance of Ethernet for plant automation (EPA) based industrial networks
A1 - Li Lu
A1 - Dong-qin Feng
A1 - Jian Chu
J0 - Journal of Zhejiang University Science C
VL - 14
IS - 6
SP - 433
EP - 448
%@ 1869-1951
Y1 - 2013
PB - Zhejiang University Press & Springer
ER -
DOI - 10.1631/jzus.C1200363


Abstract: 
real-time Ethernet (RTE) control systems with critical real-time requirements are called fast real-time (FRT) systems. To improve the real-time performance of ethernet for plant automation (EPA), we propose an EPA-FRT scheme. The minimum macrocycle of EPA networks is reduced by redefining the EPA network frame format, and the synchronization process is modified to acquire higher accuracy. A multi-segmented topology with a scheduling scheme is introduced to increase effective bandwidth utilization and reduce protocol overheads, and thus to shorten the communication cycle significantly. Performance analysis and practical tests on a prototype system show the effectiveness of the proposed scheme, which achieves the best performance at small periodic payload in large scale systems.

Darkslateblue:Affiliate; Royal Blue:Author; Turquoise:Article

Reference

[1]Cena, G., Bertolotti, I.C., Scanzio, S., Valenzano, A., Zunino, C., 2012. Evaluation of EtherCAT distributed clock performance. IEEE Trans. Ind. Inf., 8(1):20-29.

[2]Cereia, M., Bertolotti, I.C., Scanzio, S., 2011. Performance of a real-time EtherCAT master under Linux. IEEE Trans. Ind. Inf., 7(4):679-687.

[3]Chen, S.X., An, B., 2010. Time Performance Research on Field Bus Based CNC System. Proc. 2nd ICMEE, p.56-59.

[4]Decotignie, J.D., 2005. Ethernet-based real-time and industrial communications. Proc. IEEE, 93(6):1102-1117.

[5]Erwinski, K., Paprocki, M., Grzesiak, L.M., Karwowski, K., Wawrzak, A., 2013. Application of Ethernet Powerlink for communication in a Linux RTAI open CNC system. IEEE Trans. Ind. Electron., 60(2):628-636.

[6]Felser, M., 2005. Real-time Ethernet—industry prospective. Proc. IEEE, 93(6):1118-1129.

[7]Ferrari, P., Flammini, A., Vitturi, S., 2006. Performance analysis of PROFINET networks. Comput. Stand. Interf., 28(4):369-385.

[8]Ferrari, P., Flammini, A., Rinaldi, S., Sisinni, E., 2010. On the seamless interconnection of IEEE1588-based devices using a PROFINET IO infrastructure. IEEE Trans. Ind. Inf., 6(3):381-392.

[9]FF-581:2003. Fieldbus Foundation System Architecture Specification. Fieldbus Foundation, Austin, TX.

[10]Gaderer, G., Loschmidt, P., Sauter, T., 2010. Improving fault tolerance in high-precision clock synchronization. IEEE Trans. Ind. Inf., 6(2):206-215.

[11]Gao, T., Yu, D., Vue, D., Hu, Y., 2010. Design and Implementation of Communication Platform in CNC System. Proc. IEEE/ASME Int. Conf. on MESA, p.355-360.

[12]Hanzalek, Z., Burget, P., Sucha, P., 2010. PROFINET IO IRT message scheduling with temporal constraints. IEEE Trans. Ind. Inf., 6(3):369-380.

[13]Hespanha, J.P., Naghshtabrizi, P., Xu, Y.G., 2007. A survey of recent results in networked control systems. Proc. IEEE, 95(1):138-162.

[14]Hong, S.H., Song, S.M., 2008. Transmission of a scheduled message using a foundation Fieldbus protocol. IEEE Trans. Instrum. Meas., 57(2):268-275.

[15]IEC 61158-3, 4, 5, 6:2000. Digital Data Communications for Measurement and Control - Parts 3 to 6: Fieldbus for Use in Industrial Control Systems. IEC, Geneva, Switzerland.

[16]IEC 61784-1:2007. Industrial Communication Networks - Part 1: Digital Data Communications for Measurement and Control - Part 1: Profile Sets for Continuous and Discrete Manufacturing Relative to Fieldbus Use in Industrial Control Systems. IEC, Geneva, Switzerland.

[17]IEC 61784-2:2007. Digital Data Communications for Measurement and Control - Part 2: Additional Profiles for ISO/IEC8802-3 Based Communication Networks in Real-Time Applications. IEC, Geneva, Switzerland.

[18]IEC 61784-14:2007. Industrial Communication Networks - Part 14: Additional Fieldbus Profiles for Real-Time Networks Based on ISO/IEC 8802-3. IEC, Geneva, Switzerland.

[19]IEEE 1588:2008. Precision Clock Synchronization Protocol for Networked Measurement and Control Systems.

[20]IEEE 802.3:2005. Carrier Sense Multiple Access with Collision Detection (CSMA/CD) Access Method and Physical Layer Specifications.

[21]Jasperneite, J., Schumacher, M., Weber, K., 2007. Limits of Increasing the Performance of Industrial Ethernet Protocols. IEEE Conf. on Emerging Technologies & Factory Automation, p.17-24.

[22]Kim, K., Sung, M., Jin, H.W., 2012. Design and implementation of a delay-guaranteed motor drive for precision motion control. IEEE Trans. Ind. Inf., 8(2):351-365.

[23]Monmasson, E., Idkhajine, L., Cirstea, M.N., Bahri, I., Tisan, A., Naouar, M.W., 2011. FPGAs in industrial control applications. IEEE Trans. Ind. Inf., 7(2):224-243.

[24]Prytz, G., 2008. A Performance Analysis of EtherCAT and PROFINET IRT. IEEE Conf. on Emerging Technologies & Factory Automation, p.408-415.

[25]Raja, P., Ruiz, L., Decotignie, J.D., 1994. Modeling and Scheduling Real-Time Control Systems with Relative Consistency Constraints. Proc. 6th Euromicro Workshop on Real-Time Systems, p.46-52.

[26]Sauter, T., 2007. The continuing evolution of integration in manufacturing automation. IEEE Ind. Electron. Mag., 1(1):10-19.

[27]Sauter, T., 2010. The three generations of field-level networks—evolution and compatibility issues. IEEE Trans. Ind. Electron., 57(11):3585-3595.

[28]Sauter, T., Vasques, F., 2006. Special section on communication in automation. IEEE Trans. Ind. Inf., 2(2):73-77.

[29]Schumacher, M., Jasperneite, J., Weber, K., 2008. A New Approach for Increasing the Performance of the Industrial Ethernet System PROFINET. IEEE Int. Workshop on Factory Communication Systems, p.159-167.

[30]van den Heuvel, M.M.H.P., Bril, R.J., Lukkien, J.J., 2012. Transparent synchronization protocols for compositional real-time systems. IEEE Trans. Ind. Inf., 8(2):322-336.

[31]Vitturi, S., Peretti, L., Seno, L., Zigliotto, M., Zunino, C., 2011. Real-time Ethernet networks for motion control. Comput. Stand. Interf., 33(5):465-476.

Open peer comments: Debate/Discuss/Question/Opinion

<1>

Please provide your name, email address and a comment





Journal of Zhejiang University-SCIENCE, 38 Zheda Road, Hangzhou 310027, China
Tel: +86-571-87952783; E-mail: cjzhang@zju.edu.cn
Copyright © 2000 - 2024 Journal of Zhejiang University-SCIENCE