Full Text:   <2860>

CLC number: TB126

On-line Access: 2024-08-27

Received: 2023-10-17

Revision Accepted: 2024-05-08

Crosschecked: 0000-00-00

Cited: 4

Clicked: 6569

Citations:  Bibtex RefMan EndNote GB/T7714

-   Go to

Article info.
Open peer comments

Journal of Zhejiang University SCIENCE A 2005 Vol.6 No.12 P.1446-1448

http://doi.org/10.1631/jzus.2005.A1446


Design of ERT system


Author(s):  Zhu Jian-ping, Wang Bao-liang, Huang Zhi-yao, Li Hai-qing

Affiliation(s):  Department of Control Science and Engineering, Zhejiang University, Hangzhou 310027, China

Corresponding email(s):   jpzhu@iipc.zju.edu.cn, zyhuang@iipc.zju.edu.cn

Key Words:  Electrical resistance tomography (ERT), Direct current (DC), Excitation, Reconstruction


Share this article to: More <<< Previous Article|

Zhu Jian-ping, Wang Bao-liang, Huang Zhi-yao, Li Hai-qing. Design of ERT system[J]. Journal of Zhejiang University Science A, 2005, 6(12): 1446-1448.

@article{title="Design of ERT system",
author="Zhu Jian-ping, Wang Bao-liang, Huang Zhi-yao, Li Hai-qing",
journal="Journal of Zhejiang University Science A",
volume="6",
number="12",
pages="1446-1448",
year="2005",
publisher="Zhejiang University Press & Springer",
doi="10.1631/jzus.2005.A1446"
}

%0 Journal Article
%T Design of ERT system
%A Zhu Jian-ping
%A Wang Bao-liang
%A Huang Zhi-yao
%A Li Hai-qing
%J Journal of Zhejiang University SCIENCE A
%V 6
%N 12
%P 1446-1448
%@ 1673-565X
%D 2005
%I Zhejiang University Press & Springer
%DOI 10.1631/jzus.2005.A1446

TY - JOUR
T1 - Design of ERT system
A1 - Zhu Jian-ping
A1 - Wang Bao-liang
A1 - Huang Zhi-yao
A1 - Li Hai-qing
J0 - Journal of Zhejiang University Science A
VL - 6
IS - 12
SP - 1446
EP - 1448
%@ 1673-565X
Y1 - 2005
PB - Zhejiang University Press & Springer
ER -
DOI - 10.1631/jzus.2005.A1446


Abstract: 
A new electrical resistance tomography (ERT) system, based on the bi-directional current pulse technique, is developed. Polarization effects at the electrodes are eliminated. During each half cycle of the excitation process, direct current DC) is used as the excitation source and filtering is not needed. Moreover, using optimized data collection protocol, the number of current injections for a 16-electrode system is reduced to 14 for 104 independent readings of an image. Experimental results showed that the system is effective using the sensitivity coefficient algorithm for image reconstruction.

Darkslateblue:Affiliate; Royal Blue:Author; Turquoise:Article

Reference

[1] Cilliers, J.J., Xie, W., Neethling, S.J., Randall, E.W., Wilkinson, A.J., 2001. Electrical resistance tomography using a bi-directional current pulse technique. Meas. Sci. Technol., 12:997-1001.

[2] Huang, H.B., Ji, H.F., Huang, Z.Y., Li, H.Q., 2003. Design of Electrical Resistance Tomography System Based on Bi-diretional Pulsed Current Technique. Proceedings of the Sixth International Conference on Electronic Measurement and Instruments, Taiyuan, China, p.2300-2303.

[3] Tapp, H.S., Peyton, A.J., Kemsley, E.K., Wilson, R.H., 2003. Chemical engineering applications of electrical process tomography. Sensors and Actuators B, 92:17-24.

[4] van Weereld, J.J.A., Collie, D.A.L., Player, M.A., 2001. A fast resistance measurements system for impedance tomography using a bipolar DC pulse method. Meas. Sci. Technol., 12:1002-1011.

[5] Wang, B.L., Ji, H.F., Huang, Z.Y., Li, H.Q., 2005. A high-speed data acquisition system for ECT based on the differential sampling method. IEEE Sensors Journal, 5(2):308-312.

Open peer comments: Debate/Discuss/Question/Opinion

<1>

RAYMUNDO BARRALES@PROFESSOR<rbg@correo.azc.uam.mx>

2015-07-30 08:19:08

Im looking for papers on this subject

Sim@T<hangar18et@hotmail.com>

2010-11-25 18:36:37

this is very helpful to me

thank you

Please provide your name, email address and a comment





Journal of Zhejiang University-SCIENCE, 38 Zheda Road, Hangzhou 310027, China
Tel: +86-571-87952783; E-mail: cjzhang@zju.edu.cn
Copyright © 2000 - 2024 Journal of Zhejiang University-SCIENCE